PCB-3741F122G
- MEMS accelerometer
- Suitable for measuring static accelerations
- Measuring range ± 2 g pk (± 19.6m / s²)
- Sensitivity (± 3%) 1,350 mV / g (137.6mV / (m / s²))
- Frequency range (± 5%) 0 ... 250 Hz
- Supply voltage 5… 32 V DC
- Integrated connection cable, length 3 meters,
ending on stripped and tinned ends
Specifications | |||
---|---|---|---|
Basic data | English units | SI units | |
Sensitivity (± 5%) | 1.350 mV/g | 137,6 mV/(m/s²) | [1] |
Measuring range | ± 2 g pk | ±19,6 m/s²pk | |
Frequency range (± 5%) | 0 ... 250 Hz | ||
Frequency range (± 10%) | 0 ... 350 Hz | ||
Resonance frequency | 1,200 Hz | [2] | |
Phase shift (10 Hz) | <2.5 ° | ||
Broadband resolution | 0.1 mg rms | 0,001 m/s²RMS | [2] |
Linearity error | ≤1% FS | [3] | |
Lateral acceleration sensitivity | ≤3% | ||
Conditions of use | |||
Overload limit (shock) | ± 5,000 g pk | ±49.050 m/s²pk | |
Temperature range (operation) | -65 ... 250 ° F | -54.0 ... 121 ° C | |
Temperature range (storage) | -65 ... 250 ° F | -54.0 ... 121 ° C | |
Temperature coefficient of the zero point | ± 1.5% FSO | [4] [5] | |
Temperature coefficient of sensitivity | 2.5% | ||
Magnetic sensitivity | 200 g / µg / gauss | 19,6 (m/s²)Tesla | [2] |
Stretch sensitivity (base area) | 0.002 g / ml | 0.02 (m / s²) / ε | [2] |
Technical characteristics | |||
Supply voltage | 5… 32 V DC | ||
Power consumption | ≤5 mA | ||
Output impedance | ≤120 Ω | ||
Voltage offset | ±20 mVDC | [6] | |
Spectral noise (1 to 100 Hz) | 10 µg/√Hz | 98.1 (µm / s²) / √Hz | [2] |
Electrical insulation (housing) | >100 MΩ | [7] | |
Physical characteristics | |||
Housing material | Anodized aluminum | ||
seal | Epoxy resin | ||
Size - height | 0.30 in | 7.62 mm | |
Size - length | 1.00 in | 25.4 mm | |
Size - width | 0.85 in | 21.6 mm | |
Mass (without cable) | 0,35 oz | 9.92 grams | [2] |
Electrical connection | Integrated cable | ||
Cable outlet | Laterally | ||
Cable termination | Tinned ends | ||
Cable type | Type 010, shielded 4-wire cable | ||
Cable length | 10 ft | 3 m | |
Attachment | Two through holes |
Hints | |||
---|---|---|---|
[1] | Measured at 5 Hz, 0.5 g RMS | ||
[2] | Typically | ||
[3] | Zero-based best-fit line, determined using the least squares method | ||
[4] | FSO = "Full Scale Output": maximum output signal over the measuring range (4 V DC ). | ||
[5] | -54… 121 ° C, reference 24 ° C | ||
[6] | Offset tolerance for standard cable length (3 meters) | ||
[7] | Between the housing / cable shield and the mounting surface or connecting wires | ||
[8th] | Details: see PCB Declaration of Conformance PS027 |
included supply | ||
---|---|---|
081A103 | Mounting screw | (2) |
ACS-85 | Calibration of the amplitude and phase response | (1) |
M081A103 | Mounting screw and washer, thread M3 x 0.5 | (2) |
Optional accessories | ||
---|---|---|
080A208 | Triax mounting cube | (1) |