PCB-3711F1250G
    zoom_out_map

      PCB-3711F1250G

      • MEMS accelerometer
      • Suitable for measuring static accelerations
      • Measuring range ± 50 g pk (± 490m / s²)
      • Sensitivity (± 3%) 27 mV / g (2.8mV / (m / s²))
      • Frequency range (± 5%) 0… 1,500 Hz
      • Supply voltage 5… 32 V DC
      • Integrated connection cable, length 3 meters,
        ending on stripped and tinned ends
      Specifications
      Basic dataEnglish unitsSI units 
      Sensitivity (± 5%)27 mV/g2,8 mV/(m/s²)[1]
      Measuring range± 50 g pk±490 m/s²pk
      Frequency range (± 5%)0 … 1.500 Hz
      Frequency range (± 10)0 … 2.000 Hz
      Resonance frequency>6.500 Hz
      Phase response (100 Hz)<10 °
      Broadband resolution1,5 mg rms0,015 m/s²RMS[2]
      Linearitätsfehler≤1 %[3]
      Lateral acceleration sensitivity≤3 %
      Conditions of use
      Overload limit (shock)± 5,000 g pk±49.050 m/s²pk
      Temperature range (operation)-65 … 250 °F-54,0 … 121 °C
      Temperature range (storage)-65 … 250 °F-54,0 … 121 °C
      Temperature coefficient of the zero point±1,5 % FSO[4]
      Temperature coefficient of sensitivity±2,5 %[4]
      Stretch sensitivity (base area)0.001 g / ml0.01 (m / s²) / ε[2]
      Magnetic sensitivity40 µg/gauss3,9 (m/s²)Tesla[2]
      Technical characteristics
      Supply voltage5 … 32 VDC
      Power consumption≤5 mA
      Output impedance≤120 Ω
      Voltage offset±20 mVDC[5]
      Spectral Noise (1)250 µg/√Hz2.453 (µm / s²) / √Hz[2]
      Electrical insulation (housing)>100 MΩ
      Physical characteristics
      Housing materialAnodized aluminum
      sealEpoxy resin
      Size - height0,30 in7,62 mm
      Size - length1,00 in25,4 mm
      Size - width0,85 in21,6 mm
      Mass (without cable)0,35 oz9.92 grams[2]
      Electrical connectionIntegrated cable
      Cable outletLaterally
      Cable terminationTinned ends
      Cable typeType 010, shielded 4-wire cable
      Cable length10 ft3 m
      AttachmentThrough Holes (2)

      Hints
      [1]Measured at 100 Hz, 10 g RMS
      [2]Typically
      [3]Zero-based best-fit line, determined using the least squares method
      [4]-54… 121 ° C, reference 24 ° C
      [5]Offset with 3 meter cable length (type 010)
      [6]Details: siehe PCB Declaration of Conformance PS027

      included supply
      M081A113Metric mounting screw(2)
      081A113Mounting screw(2)
      ACS-172Calibration of the amplitude and phase response from 5 Hz to the upper ± 5% frequency range(1)
      PCB-3711F1250G

      Specific References

      Download

      3711B1250G_drawing.PDF

      Technical drawing

      Download (192.04k)

      3711B1250G_manual.PDF

      Operating instructions

      Download (802.29k)

      3711B1250G_specs.PDF

      Technical data sheet

      Download (443.58k)