PCB-3711F122G
    zoom_out_map

      PCB-3711F122G

      • MEMS accelerometer
      • Suitable for measuring static accelerations
      • Measuring range ± 2 g (± 19.6m / s² pk)
      • Sensitivity 675 mV / g
      • Frequency range (± 5%) 0 ... 250 Hz
      • Supply voltage 5… 32 V DC
      • Integrated connection cable, length 3 meters,
        ending on stripped and tinned ends
      Specifications
      Basic dataEnglish unitsSI units 
      Sensitivity (± 5%)675 mV/g68,8 mV/(m/s²)[6]
      Measuring range± 2 g pk±19,6 m/s²pk
      Frequency range (± 5%)0 … 250 Hz
      Frequency range (± 10%)0 … 350 Hz
      Resonance frequency1.200 Hz[2]
      Phase response (10 Hz)<2,5 °
      Broadband resolution0,1 mg rms0,001 m/s²RMS[3]
      Linearitätsfehler≤1 %[2]
      Lateral acceleration sensitivity≤3 %
      Conditions of use
      Overload limit (shock)± 5,000 g pk±49.050 m/s²pk
      Temperature range (operation)-65 … 250 °F-54 … 121 °C
      Temperature range (storage)-65 … 250 °F-54 … 121 °C
      Temperature coefficient of sensitivity±2,5 %[1]
      Temperature coefficient of the zero point±1,5 % FSO[1]
      Stretch sensitivity (base area)0.001 g / ml0.01 (m / s²) / ε[3]
      Magnetic sensitivity200 µg/Gs19,6 (m/s²)/T[3]
      Technical characteristics
      Supply voltage5 … 32 VDC
      Power consumption≤5 mA
      Output impedance≤120 Ω
      Voltage offset-20 … 20 mVDC[4]
      Spectral Noise (1)10 µg/√Hz98.1 (µm / s²) / √Hz[3]
      Electrical insulation (housing)>100 MΩ
      Physical characteristics
      Housing materialTitan
      sealHermetically sealed
      Size - height0,45 in11,4 mm
      Size - length0,85 in21,6 mm
      Size - width0,85 in21,6 mm
      Ground (with cable)2,29 oz65.0 grams
      Electrical connectionIntegrated cable
      AKabelabgangLaterally
      Cable terminationTinned ends
      Cable typeType 010, shielded 4-wire cable
      Cable length10 ft3 m
      AttachmentThrough hole

      Hints
      [1]-54… 121 ° C, reference 24 ° C
      [2]Zero-based best-fit line, determined using the least squares method
      [3]Typically
      [4]Offset with 3 meter cable length (type 010)
      [5]Details: siehe PCB Declaration of Conformance PS027
      [6]Measured at 5 Hz, 0.5 grams.

      included supply
      080A152Fastening clip(1)
      081A113Mounting screw(2)
      ACS-85Calibration of the amplitude and phase response(1)
      M081A113Metric mounting screw(2)
      PCB-3711F122G

      Specific References

      Download

      3711B122G_drawing.PDF

      Technical drawing

      Download (192.04k)

      3711B122G_manual.PDF

      Operating instructions

      Download (780.92k)

      3711B122G_specs.PDF

      Technical data sheet

      Download (422.21k)