PCB-3711F12200G
    zoom_out_map

      PCB-3711F12200G

      • MEMS accelerometer
      • Suitable for measuring static accelerations
      • Measuring range ± 200 g pk (± 1960m / s²)
      • Sensitivity (± 3%) 6.75 mV / g (0.69mV / (m / s²))
      • Frequency range (± 5%) 0… 1,500 Hz
      • Supply voltage 5… 32 V DC
      • Integrated connection cable, length 3 meters,
        ending on stripped and tinned ends
      Specifications
      Basic dataEnglish unitsSI units 
      Sensitivity (± 10%)6,75 mV/g0,69 mV/(m/s²)[6]
      Measuring range± 200 g pk±1.960 m/s²pk
      Frequency range (± 5%)0 … 1.500 Hz
      Frequency range (± 10%)0 … 2.500 Hz
      Resonance frequency11.800 Hz
      Phase response (100 Hz)<10 °
      Broadband resolution6 mg rms0,6 m/s²RMS[3]
      Linearitätsfehler≤1 %[2]
      Lateral acceleration sensitivity≤3 %
      Conditions of use
      Overload limit (shock)± 5,000 g pk±49.050 m/s²pk
      Temperature range (operation)-65 … 250 °F-54 … 121 °C
      Temperature range (storage)-65 … 250 °F-54 … 121 °C
      Temperature coefficient of sensitivity±2,5 %[1]
      Temperature coefficient of the zero point±1,5 % FSO[1]
      Stretch sensitivity (base area)0.001 g / ml0.01 (m / s²) / ε[3]
      Magnetic sensitivity40 µg/Gs3,9 (m/s²)/T[3]
      Technical characteristics
      Supply voltage5 … 32 VDC
      Power consumption≤5 mA
      Output impedance≤120 Ω
      Voltage offset±20 mVDC[4]
      Spectral Noise (1)800 µg/√Hz7,848 (µm / s²) / √Hz[3]
      Electrical insulation (housing)>100 MΩ
      Physical characteristics
      Housing materialTitan
      sealHermetically sealed
      Size - height0,45 in11,4 mm
      Size - length0,85 in21,6 mm
      Size - width0,85 in21,6 mm
      Ground (with cable)2,29 oz65.0 grams
      Electrical connectionIntegrated cable
      Cable outletLaterally
      Cable terminationTinned ends
      Cable typeType 010, shielded 4-wire cable
      Cable length10 ft3 m
      AttachmentThrough hole

      Hints
      [1]-54… 121 ° C, reference 24 ° C
      [2]Zero-based best-fit line, determined using the least squares method
      [3]Typically
      [4]Offset with 3 meter cable length (type 010)
      [5]Details: siehe PCB Declaration of Conformance PS027
      [6]Measured at 100 Hz, 1 grms.

      included supply
      080A152Fastening clip(1)
      081A113Mounting screw(2)
      ACS-172Calibration of the amplitude and phase response from 5 Hz to the upper ± 5% frequency range(1)
      M081A113Metric mounting screw(2)
      PCB-3711F12200G

      Specific References

      Download

      3711B12200G_drawing.PDF

      Technical drawing

      Download (192.04k)

      3711B12200G_manual.PDF

      Operating instructions

      Download (786.97k)

      3711B12200G_specs.PDF

      Technical data sheet

      Download (428.26k)