PCB-3711F12200G
- MEMS accelerometer
- Suitable for measuring static accelerations
- Measuring range ± 200 g pk (± 1960m / s²)
- Sensitivity (± 3%) 6.75 mV / g (0.69mV / (m / s²))
- Frequency range (± 5%) 0… 1,500 Hz
- Supply voltage 5… 32 V DC
- Integrated connection cable, length 3 meters,
ending on stripped and tinned ends
| Specifications | |||
|---|---|---|---|
| Basic data | English units | SI units | |
| Sensitivity (± 10%) | 6,75 mV/g | 0,69 mV/(m/s²) | [6] |
| Measuring range | ± 200 g pk | ±1.960 m/s²pk | |
| Frequency range (± 5%) | 0 … 1.500 Hz | ||
| Frequency range (± 10%) | 0 … 2.500 Hz | ||
| Resonance frequency | 11.800 Hz | ||
| Phase response (100 Hz) | <10 ° | ||
| Broadband resolution | 6 mg rms | 0,6 m/s²RMS | [3] |
| Linearitätsfehler | ≤1 % | [2] | |
| Lateral acceleration sensitivity | ≤3 % | ||
| Conditions of use | |||
| Overload limit (shock) | ± 5,000 g pk | ±49.050 m/s²pk | |
| Temperature range (operation) | -65 … 250 °F | -54 … 121 °C | |
| Temperature range (storage) | -65 … 250 °F | -54 … 121 °C | |
| Temperature coefficient of sensitivity | ±2,5 % | [1] | |
| Temperature coefficient of the zero point | ±1,5 % FSO | [1] | |
| Stretch sensitivity (base area) | 0.001 g / ml | 0.01 (m / s²) / ε | [3] |
| Magnetic sensitivity | 40 µg/Gs | 3,9 (m/s²)/T | [3] |
| Technical characteristics | |||
| Supply voltage | 5 … 32 VDC | ||
| Power consumption | ≤5 mA | ||
| Output impedance | ≤120 Ω | ||
| Voltage offset | ±20 mVDC | [4] | |
| Spectral Noise (1) | 800 µg/√Hz | 7,848 (µm / s²) / √Hz | [3] |
| Electrical insulation (housing) | >100 MΩ | ||
| Physical characteristics | |||
| Housing material | Titan | ||
| seal | Hermetically sealed | ||
| Size - height | 0,45 in | 11,4 mm | |
| Size - length | 0,85 in | 21,6 mm | |
| Size - width | 0,85 in | 21,6 mm | |
| Ground (with cable) | 2,29 oz | 65.0 grams | |
| Electrical connection | Integrated cable | ||
| Cable outlet | Laterally | ||
| Cable termination | Tinned ends | ||
| Cable type | Type 010, shielded 4-wire cable | ||
| Cable length | 10 ft | 3 m | |
| Attachment | Through hole | ||
| Hints | |||
|---|---|---|---|
| [1] | -54… 121 ° C, reference 24 ° C | ||
| [2] | Zero-based best-fit line, determined using the least squares method | ||
| [3] | Typically | ||
| [4] | Offset with 3 meter cable length (type 010) | ||
| [5] | Details: siehe PCB Declaration of Conformance PS027 | ||
| [6] | Measured at 100 Hz, 1 grms. | ||
| included supply | ||
|---|---|---|
| 080A152 | Fastening clip | (1) |
| 081A113 | Mounting screw | (2) |
| ACS-172 | Calibration of the amplitude and phase response from 5 Hz to the upper ± 5% frequency range | (1) |
| M081A113 | Metric mounting screw | (2) |