PCB-3711F112G
    zoom_out_map

      PCB-3711F112G

      • MEMS DC accelerometer
      • Suitable for measuring static accelerations
      • Measuring range ± 2 g pk (± 19.6m / s² pk)
      • Sensitivity 675 mV / g (68.8 mV / (m / s²))
      • Typical frequency range (± 5%) 0 ... 250 Hz
      • Supply voltage 5… 32 V DC
      • 4-pin connection socket on the side
      Specifications
      Basic dataEnglish unitsSI units 
      Sensitivity (± 3%)675 mV/g68,8 mV/(m/s²)[7]
      Measuring range±2 g pk±19,6 m/s² pk
      Frequency range (± 5%)0 … 250 Hz
      Frequenz­bereich (±10%)0 … 350 Hz
      Resonance frequency1,2 kHz[2]
      Phase response (10Hz)<2,5 °
      Broadband resolution (0.5 ... 100 Hz)0,1 mg rms0,001 m/s² rms[2]
      Linearitätsfehler≤1 %[1]
      Lateral acceleration sensitivity≤3 %
      Conditions of use
      Overload limit (shock)±5.000 g pk±49.050 m/s² pk
      Temperature range (operation)-65 … 250 °F-54 … 121 °C
      Temperature range (storage)-65 … 250 °F-54 … 121 °C
      Temperature coefficient of sensitivity±2,5 %[4]
      Temperature coefficient of the zero point±1,5 % FSO[4]
      Stretch sensitivity (base area)0.001 g / ml0.01 (m / s²) / ε[2]
      Magnetic sensitivity200 µg/Gs19,6 (m/s²)/T[2]
      Technical characteristics
      Supply voltage5 … 32 VDC
      Power consumption≤5 mA
      Output impedance≤120 Ω
      Voltage offset±20 mVDC[5]
      Spectral noise (1 ... 100 Hz)10 µg/√Hz98.1 (µm / s²) / √Hz[2]
      Electrical insulation (base)>100 MΩ
      Physical characteristics
      Housing materialTitan
      sealHermetically sealed
      Size - height0,45 in11,4 mm
      Size - length0,85 in21,6 mm
      Size - width0,85 in21,6 mm
      Mass0,58 oz16.3 grams
      Electrical connection4-Pin
      connectionLaterally
      AttachmentTwo through holes

      Hints
      [1]Zero-based best-fit line, determined using the least squares method
      [2]Typically
      [3]Guaranteed; evidenced by the calibration certificate supplied
      [4]-54… 121 ° C, reference 24 ° C
      [5]Offset with 3 meter cable length (type 010)
      [6]Details: siehe PCB Declaration of Conformance PS027
      [7]Measured at 5 Hz, 0.5 grams.

      included supply
      080A152Fastening clip(1)
      081A113Mounting screw with 4-40 thread(2)
      M081A113Mounting screw with M2.5 thread(2)
      ACS-85Calibration of the amplitude and phase response from 5 Hz to the upper ± 5% frequency range(1)
      PCB-3711F112G

      Specific References

      Download

      3711E112G_drawing.PDF

      Technical drawing

      Download (200.7k)

      3711E112G_manual.PDF

      Operating instructions

      Download (393.5k)

      3711E112G_specs.PDF

      Technical data sheet

      Download (80.44k)