PCB-(M)621B51
basic data | |||
sensitivity (±5%) | 100 mV/g | 10.2 mV/(m/s²) | [6] |
measuring range | ±50 g | ±490 m / s² | |
Frequency range (±5%) | 144 … 600,000 cpm | 2.4 … 10,000 Hz | [1] |
frequency range (± 10%) | 102 … 900,000 cpm | 1.7 … 15,000 Hz | |
frequency range (± 3 dB) | 48 … 1.200,000 cpm | 0.8 … 20,000 Hz | |
resonance frequency | 2,100 kcpm | 35,000 Hz | |
linearity | ≤1% | [2] | |
transverse acceleration sensitivity | ≤ 5% | ||
Conditions of use | |||
5,000 g pk | 49,050 m/s² pk | Overload limit (shock) | |
Temperature range | -65 … 250 ° F | -54 … 121 ° C | |
technical characteristics | |||
settling time (on bias voltage ± 1%) | ≤ 5.0 s | ||
Mass | 1.06 oz | 30 g | |
mounting thread | 10-32 female thread | [4] | |
Assembly torque | 10 … 20 in-lb | 1.13 … 2.26 Nm | |
sensor element | ceramic | ||
geometry of the sensor element | shear principle | ||
Housing material | stainless steel | ||
sealing | hermetically sealed welded | ||
electric Port | 10-32-coaxial socket | ||
connection position | side | ||
notes | |||
[1] | tolerance of the upper cutoff frequency: ±10% | ||
[2] | zero-based balancing line, determined using the method of least squares | ||
[3] | typical value | ||
[4] | no equivalent in SI units | ||
[5] | typically | ||
[6] | Conversion factor 1 g = 9.81 m/s² | ||
Accessories | |||
ICS-1 | frequency response for uniaxial sensors from 10 Hz up to the upper 5% frequency | -1 | |
(M) metric mounting | |||
Accessories supplied | |||
M081B05 | metric mounting bolts with M6 fine thread | -1 |