PCB-(M)608A11/010AC
- Industrial ICP® vibration sensor, li >
- Measurement range 50 g,
- Sensitivity 100 mV/g,
- Frequency range 0.5... 10,000 Hz,
- One-point calibration at 100 Hz,
- Integrated cable, length 3 m,
ending on BNC connector
| Basic data | ||||
| Sensitivity (± 15 %) | 10.2 mV/(m/s²) | [2] | ||
| Measuring range | ±50 g | ±490 m/s² | ||
| Frequency range (± 3 dB) | 30... 600,000 cpm | 0.5... 10,000 Hz | ||
| Resonance frequency | 1,320 kcpm | 22,000 Hz | [3] | |
| Wide band resolution | 350 µg | 3.434 µm / s ² | [3] | |
| Linearity error | ±1 % | [4] | ||
| Transverse acceleration sensitivity | ≤7% | |||
| Conditions of use | ||||
| Overload limit (shock) | 5,000 g PK | 49,050 m/s² PK | ||
| Temperature range | -65... 250 ° F | -54... 121 ° C | ||
| Type of protection | IP68 | |||
| Technical properties | ||||
| Settling time (on bias voltage ±1 %) | ≥2,0 s | |||
| discharging charging time constant | ≤0,3 s | |||
| power | 18... 28 V DC | |||
| constant power supply | 2... 20 mA | |||
| output impedance | >150Ω | |||
| Bias voltage | 8... 12 V DC | |||
| spectral noise (10 Hz) | 8 µg/√Hz | 78.5 (µm/s²)/√Hz | [3] | |
| spectral noise (100 Hz ) | 5 µg/√Hz | 49.1 (µm/s²)/√Hz | [3] | |
| spectral noise (1,000 Hz) | 4 µg/√Hz | 39.2 (µm/s²)/√Hz | [3] | |
| electrical insulation (housing) | >100 MΩ | |||
| Physical properties | ||||
| size - Allen | 9/16 in | 14 mm | ||
| size - height | 2.5 in | 64 mm | ||
| Weight (with cord) | 3.5 oz | 99.3 grams | ||
| Fixing | Mounting bolts | |||
| Installation torque | 2... 5 ft-lb | 2.7... 6.8 Nm | ||
| Sensor element | Ceramic | |||
| Geometry of the sensor element | Shear principle | |||
| Housing material | Stainless steel | |||
| Sealing | Shed | |||
| Electrical connection | Potted integrated cable | |||
| Cable outlet | Top | |||
| Cable termination | BNC connector | |||
| Cable length | 10 ft | 3 m | ||
| Cable type | Polyurethane | [1] | ||
| Notes | ||||
| [1] | Two-wire shielded cable with twisted pair wires | |||
| [2] | Conversion factor 1 g = 9.81 m/s² | |||
| [3] | Typischerweise | |||
| [4] | Zero-balance just, determined using the method of least squares | |||
| [5] | Details: see PCBs Declaration of conformance PS023 and PS060 | |||
| Included accessories | ||||
| 081A40 | Mounting bolts with 1/4 "-28 thread" | -1 | ||
| ICS-2 | One-point calibration at 100 Hz (traceable to NIST) | -1 | ||
| (M) metric mounting | ||||
| Included accessories | ||||
| M081A61 | Metric mounting bolts with M6 threads | -1 | ||
| (TO) Temperature output | ||||
| Temperature range | 36... 250 ° F | 2... 121 ° C | ||
| Transfer factor | 5.56 mV / ° F (Zero point at 32 ° F) | 10 mV / ° C | ||
| Electrical connection | Potted integrated cable | |||
| Terminal assigNment (red wire) | Acceleration output | |||
| Terminal assigNment (black wire) | Mass | |||
| Terminal assigNment (white wire) | Temperature output | |||
| (EX) With ATEX approval | ||||
| Approved for use in potentially explosive atmospheres | CL I, div 2, groups A, B, C, D ExnL IIC T4, AExnA IIC T4 | |||
| Approved for use in potentially explosive atmospheres | EEx nL IIC T4,-40 ° C≤Ta≤121 ° C, II 3 G | |||
| Approved for use in potentially explosive atmospheres | EEx nL IIC T4,-40 ° C≤Ta≤121 ° C, II 1 G | |||
| Approved for use in potentially explosive atmospheres | CL I, div I, groups A, B, C, D CL II, div I, groups E, F, G CL III, div I | |||
| Approved for use in potentially explosive atmospheres | ExIA IIC T4, AExia IIC, T4 | |||
| (LB) Low bias voltage | ||||
| Bias voltage | 4.8... 6.5 V DC | |||
| Supply voltage | 12... 28 V DC | |||
| Measuring range | ±10 g | ±98 m/s² |