PCB-637A06
    zoom_out_map

      PCB-637A06

      • Industrial ICP® vibration sensor, 
      • Quartz sensor element, 
      • Temperature range -196 ... +121 ° C, 
      • Measuring range 200 g, 
      • Sensitivity 25 mV / g, 
      • Frequency range 0.2 ... 1500 Hz, 
      • 2-pin connector at the top
      specifications
      basic dataEnglish unitsSI units 
      Sensitivity (± 10%)25 mV/g2,54 mV/(m/s²)[2]
      measuring range±200 g±1962 m/s²
      Frequency range (± 5%)600 … 24.000 cpm10 … 400 Hz[3]
      Frequency range (± 3 dB)240 … 90.000 cpm4 … 1.500 Hz
      resonant frequency≥1.200 kcpm≥20.000 Hz[1]
      Broadband resolution1 µg rms0,01 µm/s² rms[1]
      linearity error±1 %[4]
      Lateral acceleration sensitivity≤5 %
      Operating conditions
      Overload limit (shock)1000 g pk9.810 m/s²pk
      temperature range-320 … 250 °F-196 … 121 °C
      Technical characteristics
      Settling time (on bias voltage ± 1%)≤3,0 s
      discharging≥0,05 s≥0,5 s
      supply voltage18 … 28 VDC
      Constant current supply1,6… 20 mA
      output impedance<100 Ω
      Bias voltage7 … 11 VDC
      Spectral noise (1 Hz)600 µg/√Hz5890 (µm/s²)/√Hz
      Spectral noise (10 Hz)120 µg/√Hz1180 (µm/s²)/√Hz[1]
      Spectral noise (100 Hz)36 µg/√Hz355 (µm/s²)/√Hz[1]
      Spectral noise (1 kHz)25 µg/√Hz250 (µm/s²)/√Hz[1]
      Spectral noise (10 kHz)6 µg/√Hz59 (µm/s²)/√Hz
      Electrical insulation>100 MΩ
      Physical properties
      Size - hexagon7/8 in22 mm
      Size - hexagon7/8 in22 mm
      Size - height2,06 in52,3 mm
      Mass3,3 oz94 grams
      mounting thread1/4 "-28 female threadNo equivalent[5]
      Montagedrehmoment2 … 5 ft-lb2,7 … 6,8 Nm
      sensor elementQuartz
      Geometry of the sensor elementScherprinzip
      housing materialstainless steel
      sealHermetically sealed[6]
      Electrical connection2 pin socket (MIL-C-5015)
      port locationAbove

      [7]

      Hints
      [1]typically,
      [2]Conversion factor 1 g = 9,81 m / s²
      [3]1Hz = 60 cpm (cycles per minute)
      [4]Zero-based balancing line, determined by the least squares method
      [5]1/4-28 has no equivalent in S.I. units.
      [6]Design hydro tested to 1450 psi [10,000 kPa]
      [7]Details: siehe PCB Declaration of Conformance PS023

      included supply
      081A40Mounting bolt with 1/4 "-28 thread(1)
      ICS-6Frequency response for uniaxial transducers from 10 Hz to the upper ± 3dB point(1)

      Available options
      (M) Metric montage
      included supply
      M081A61Metric mounting bolt with M6 thread(1)
      PCB-637A06

      Specific References

      Download

      637A06_specs

      Download (94.24k)

      637A06_drawing

      Download (86.63k)

      637A06_manual