PCB-(M)607M83
zoom_out_map

PCB-(M)607M83

  • Industrial ICP® vibration sensor 
    in 3- wire technology
  • No ICP® sensor power required
  • Measuring range 45 g
  • Sensitivity 100 mV / g
  • Frequency range 1.5 ... 10.000 Hz
  • One-point calibration at 100 Hz
  • Freely orientable integrated connection cable, length 3 meters, 
    ending on cut end
specifications
basic dataEnglish unitsSI units 
Sensitivity (± 20%) 100 mV/g 10,2 mV/(m/s²) [1]
measuring range ±45 g ±441 m/s² [4]
Frequency range (± 3 dB) 90 … 600.000 cpm 1,5 … 10.000 Hz
resonant frequency 1.500 kcpm 25.000 Hz [2]
Broadband resolution (1 ... 10,000 Hz) 2 mg 19,6 mm/s² [2]
linearity error ±1 % [3]
Lateral acceleration sensitivity ≤7 %
Operating conditions
Overload limit (shock) 5.000 g pk 49.050 m/s²pk
temperature range -65 … 250 °F -54 … 121 °C
protection IP68
Technical characteristics
Settling time (on bias voltage ± 1%) ≤5,0 s
discharging ≥0,1 s
supply voltage 3 … 12 VDC
output impedance <100 Ω
current consumption 0.5 mA
Bias voltage 1,5 … 6 VDC
Spectral noise (10 Hz) 18 µg/√Hz 176,6 (µm/s²)/√Hz [2]
Spectral noise (100 Hz) 4 µg/√Hz 39,2 (µm/s²)/√Hz [2]
Spectral noise (1,000 Hz) 2 µg/√Hz 19,6 (µm/s²)/√Hz [2]
Electrical insulation (housing) >100 MΩ
Physical properties
Size - hexagon 9/16 in 14 mm
Size - height 0,97 in 24,6 mm
Mass (without cable) 1,1 oz 31 grams [5]
attachment mounting bolts
mounting thread 1/4 "-28 male thread no metric equivalent [6]
Mounting torque (mounting bolt) 7 … 8 ft-lb 9,5 … 10,8 Nm [7][8]
Assembly torque (hexagon union nut) 2 … 5 ft-lb 2,7 … 6,8 Nm
sensor element ceramics
Geometry of the sensor element Scherprinzip
housing material stainless steel
seal Hermetically sealed
Electrical connection Potted integrated cable
port location Laterally
cable termination Cut off end
Pin assignment (red wire) Supply positive (+)
Pin assignment (black wire) Mass
Pin assignment (white wire) acceleration output
cable length 10 ft 3,0 m
cable type Polyurethan

Hints
[1] Conversion factor 1 g = 9,81 m / s²
[2] typically,
[3] Zero-based balancing line, determined by the least squares method
[4] Full measuring range only with sufficiently high supply voltage
[5] With mounting bolts
[6] No equivalent in SI units
[7] Installation requires 1/8 "hex keys (for imperial mounting bolts) or 3 mm (for metric mounting bolts).
[8] The mounting bolt must be tightened with a higher torque than the hexagon union nut, so that the sensor can be dismantled easily.

included supply
080A156 Mounting bolt 1/2 "-20 to 1/4" -28 (1)
ICS-2 One-point calibration at 100 Hz (traceable to NIST) (1)

Available options
(M) Metric montage
included supply
M080A159A Mounting bolt 1/2 "-20 to M6 x 1 (1)
PCB-(M)607M83

Specific References

Download

607M83_manual.pdf

Download (462.61k)

607M83_specs.pdf

Download (79.63k)