PCB-EX619A11
- Vibration sensor with charge output,
- With ATEX/CSA approval,
- Continuous use temperature up to 482 ° C,
- With through-holes
- Measuring range 500 g,
- Sensitivity 50 pC/g,
- Upper cutoff frequency 5,000 Hz,
- Integrated hardline cable, length 3 m,
ending on 2-pin connector
| specifications | |||
|---|---|---|---|
| basic data | English units | SI units | |
| Sensitivity (± 5%) | 50 pC / g | 5.1 pC / (m / s) | |
| measuring range | ± 500 g pk | ± 4,905 m / s² pk | |
| Frequency range (± 5%) | 3000 Hz | [3] | |
| Frequency range (+ 10%) | 5000 Hz | [3] | |
| resonant frequency | > 18,000 Hz | [1] | |
| linearity error | ≤1% | [4] | |
| Lateral acceleration sensitivity | ≤5% | [2] | |
| Operating conditions | |||
| Overload limit (shock) | ± 2,000 g pk | ± 19,620 m / s² pk | |
| temperature range | -65 ... 900 ° F | -54 ... 482 ° C | |
| Strain sensitivity (base surface) | ≤0,033 g / µε | ≤0,32 (m / s²) / µε | [1] |
| Technical Specifications | |||
| Capacity (from pin to pin) | 1525 pF | [1] | |
| Capacity (from pin on housing) | 250 pF | [1] | |
| Insulation resistance (from pin on housing at 70 ° F) | > 1,000 MΩ | [1] | |
| Insulation resistance (from pin to pin at 70 ° F) | > 1,000 MΩ | ||
| Insulation resistance (from pin to pin at 900 ° F) | > 100 kΩ | ||
| output polarity | differential | ||
| physical properties | |||
| sensor element | ceramics | ||
| Geometry of the sensor element | compression principle | ||
| housing material | Inconel | ||
| seal | Hermetically | ||
| Size - Height | 1.49 in | 38 mm | |
| Size - Length | 1.63 in | 41.4 mm | |
| Size - Width | 1.63 in | 41.4 mm | |
| Mass (wired) | 19.4oz | 550 grams | [1] |
| electrical connection | Integrated Hardline cable | ||
| cable outlet | Laterally | ||
| cable length | 7 ft | 2,1 m | |
| cable termination | 2-pin socket (MIL-C-5015) | ||
| Assembly | With four through bolts | ||


| Hints | |||
|---|---|---|---|
| [1] | typically, | ||
| [2] | Lateral acceleration sensitivity typically ≤ 3% | ||
| [3] | The lower frequency limit depends on the used signal processing electronics. | ||
| [4] | Zero-based line of best fit, determined by the method of least squares | ||
| [5] | Details: see PCB Declaration of Conformance PS141 | ||
| included supply | ||
|---|---|---|
| 62177-01 | Screw 1/4 "-28, length 31.8 mm | (4) |
| ICS-1 | Calibration frequency response of 10 Hz to the upper 5% -frequency | (1) |