PCB-(M)642A11
basic data | |||
range | 0,0 … 1 in / s pk | 0 … 25.4 mm / s pk | [1] | "
Output area | 4 … 20 mA | ||
frequency range (± 10%) | 180 … 60,000 cpm | 3 … 1,000 Hz | [2] [3] |
Wide band resolution | 0.005 in / s pk | 0.13 mm / s pk | [4] |
linearity error | ≤1% | ||
conditions of use | |||
temperature range | -40 … 185 ° F | -40 … 85 ° C | |
technical characteristics | |||
Supply voltage | 12 … 30 V DC | ||
settling time (area within ±2% of full scale) | <15 s | ||
electrical insulation (housing) | ≥ 100 MΩ | ||
physical properties | |||
size - hex | 7/8 in | 22.2 mm | |
Size - height | 1.41 in | 35.8 mm | |
dimensions (without cable) | 3.8 oz | 108 grams | |
Mounting thread | ¾-16 female thread | ||
Assembly torque | 3 … 5 ft-lb | 4 … 7 Nm | |
sensor element | ceramic | ||
Geometry of the sensor element | shear principle | ||
housing material | stainless steel | ||
Sealing | hermetically sealed welded | ||
Electrical connection | integrated cable | ||
cable exit | side | ||
cable termination | Cut off end of | ||
connections (red wire) | output signal 4 … 20 mA positive | ||
pin assigNment (blue wire) | 4 output … 20mA negative | ||
cable length | 10 ft | 3.0 m | |
cable type | polyurethane | ||
Notes | |||
[1] | conversion factor 1 in / sec = 0.0254 m/sec. | ||
[2] | 1 Hz 60 = cpm ("Cycles Per Minute": rpm). | ||
[3] | frequencies below 5 Hz, the output signal fluctuates. | ||
[4] | typical value | ||
[5] | details: see PCB Declaration of Conformance PS039 and PS053 | ||
equipment | |||
080A162 | mounting bolt ¾-16 on 1/4 " 28 | -1 | |
ICS-4 | frequency response cpm for uniaxial sensors from 0 (0 Hz) up to the upper 10% frequency of vibration transmitter | -1 | |
(EX) with ATEX approval | |||
Approval for use in potentially explosive atmospheres | DIV II, CL I, GRPS A-D, ExnL, AExnA, IIC T4 | ||
approval for use in potentially explosive atmospheres | EEx ia IIC T4,-40 ° C ≤ Ta ≤ 80 ° C, II 1 G | ||
Admission f &kitchen r hazardous atmospheres | EEx nL IIC T4,-40 ° C ≤ Ta ≤ 80 ° C, II 3 G | ||
approval for use in potentially explosive atmospheres | DIV I, CL I, II, III, GRPS A-G, ExIA, AExia, IIC T4 | ||
(RV) raw signal output≥ 100 MΩ/g (±20%) | |||
electrical connection | integrated cable | ||
Terminal assigNment (red wire) | output signal 4 … 20 mA positive | ||
(black wire) pin assigNment | output signal 4 … 20mA negative | ||
Connections (white wire) | raw signal positive | ||
pin assigNment (green wire) | raw signal negative | ||
(M) metric Assembly | |||
equipment | |||
M080A163 | mounting bolts M6 x ¾-16 1 | -1 |