PCB-422E53
zoom_out_map

PCB-422E53

  • Inline charge amplifier,
  • Input range ±5. 000 pC,
  • Output range ±5 V,
  • Transcription factor: 1 mV / pC,
  • Frequency range 5 … 100,000 Hz (depends on the constant current)
  • of
    basic data
    transcription factor (±2. 5%) 1 mV / pC
    entrance ±5. 000 pC
    Range ±8 V
    lower limiting frequency (-5%) 5 Hz
    upper cut-off frequency (-5%) 100,000 Hz [2]
    linearity error 1.0% FS
    conditions of use
    temperature range (operation) -65 … 250 ° F -54 … 121 ° C
    maximum shock resistance 5,000 g pk pk/49,050 s²
    Maximum acceleration (5) 100 g pk 981 m/s² pk
    Technical characteristics
    Supply voltage 18 … 28 V DC
    Constant power supply 2 … 20 mA
    Output area ±5, 0 V
    output impedance 100 Ω
    Bias voltage 9 … 13 V DC
    Maximum sensor input voltage40 V
    wide band noise (1 … 10,000 Hz) 33 µV -90 dB [1]
    Spectral noise (1 Hz) 9.8 µV / √ Hz -100 dB [1]
    spectral noise (10 Hz) 3 µV / √ Hz -110 dB [1]
    Spectral noise (100 Hz) 0.8 µV / √ Hz -122 dB [1]
    spectral noise (1,000 Hz) 0.4 µV / √ Hz -128 dB [1]
    Spectral noise (10,000 Hz) 0.2 MV / √ Hz -134 dB [1]
    capacity (feedback branch of the amplifier) 1,000 pF
    Recovery time after clipping 10 µs
    discharging charging time constant > 0.1 s
    Resistance (feedback branch of the amplifier) 15,000 M Ω [3]
    influence of the input capacitance (sensor + cable) on transcription factor 0.00≤5 %/PF
    physical properties
    housing material stainless steel
    waterproofing epoxy resin
    Electrical connection (input) 10-32-coaxial socket
    electrical connection (output) BNC Plug
    Gr öße - diameter 0.52 in 13 mm
    size - length 3.4 in 86 mm
    mass 1.15 oz 32.7 grams
    Notes
    [1] tested with a voltage source and a capacitor (to simulate of a sensor)
    [2] the upper cutoff frequency can be reduced by the amount of constant current and the length of the cable output used.
    [3] ways of amplifier electronics coming to the use of must discharge charge time constantbe calculated on the basis of three times the resistance value in the feedback industry.
    [4] details: see PCBs Declaration of conformance PS024. CE conformity is only guaranteed, if the housing is earthed.
    PCB-422E53

    Specific References

    Download

    422E53_drawing.PDF

    Technical drawing

    Download (392.17k)

    422E53_manual.PDF

    Operating instructions

    Download (538.02k)

    422E53_specs.PDF

    Technical data sheet

    Download (27.13k)