PCB-HT356A63
    zoom_out_map

      PCB-HT356A63

    • Triaxial ICP® high-temperature vibration sensor,
    • Continuous use temperature up to 163 ° C,
    • With built-in low-pass filter,
    • Measuring range 500 g
    • Sensitivity 10 mV / g,
    • Frequency range 2 … 4,000 Hz,
    • 4-pin female connector on the side
    • basic data
      sensitivity (±15%)10 mV / g1.02 mV/(m/s²)
      range±500 g pk ±4. 905 m/s 2 pk
      frequency range (-5%)2 … 4,000 Hz
      Resonance frequency≥ 55,000 Hz
      Edge steepness of the filter6 dB/octave[1]
      electric filter corner frequency15,000 Hz[1]
      Wide band resolution0.008 g RMS0.08 m/s² RMS[1]
      Linearity error≤ 1%[3]
      transverse acceleration sensitivity≤ 5%
      conditions
      Overload limit (Shock)±10. 000 g pk ±98.100 m/s² pk
      Temperature range (Operation)-65 … 325 ° F-54 … 163 ° C[2]
      specifications
      power supply18 … 30 V DC
      Constant power supply2 … 20 mA
      output impedance≤200Ω
      Bias voltage7 … 11 V DC
      Discharging charging time constant0.3 … 1,0 s
      settlingbr(auf Bias-Spannung ±10 %)< 3 s
      Spectral noise (1 Hz)445 µg / √ Hz4,365 (µm / s ²) / √ Hz[1]
      spectral noise (10 Hz)135 µg / √ Hz1,325 (µm / s ²) / √ Hz[1]
      spectral noise (100 Hz)90 µg / √ Hz883 (µm / s ²) / √ Hz[1]
      spectral noise (1,000 Hz)80 µg /. √ Hz785 (µm / s ²) / √ Hz[1]
      physical properties
      Sensorelementceramic
      geometry of the sensor elementshear principle
      housing materialtitanium
      Sealinghermetically sealed
      size - height0.40 in10.2 mm
      size - length0.77 in19.6 mm
      size - width0.40 in10.2 mm
      mass0.19 oz5.3 grams[1]
      Wiring1/4 "-28 4-pin
      connection positionside
      mounting thread5-40" female
      Assembly torque4 … 5 in-lb45 … 56 NCM
      notes
      [1]typically
      [2]the data for temperatures above 121 ° C applies only for transducers with HT option.
      [3]zero-based balancing line, determined using the method of least squares
      [4]details: see PCBs Declaration of conformance PS023
      equipment
      080A Adhesive mounting-1
      081A27mounting bolts, 5-40 on 5-40-1
      081A90mounting bolts, 10-32 on 5-40-1
      ACS-1Tfrequency response for Triaxial accelerometer, traceable to NIST, 10 Hz up to the upper 5% frequency-1
      M081A27metric mounting bolts, 5-40 M3 x 0.50-1
      Additional information
      Featuresbuilt-in low-pass filter with low cut-off frequency
    • weight
    • PCB-HT356A63

      Specific References

      Download

      356A63_drawing.PDF

      Technical drawing

      Download (44.26k)

      356A63_specs.PDF

      Technical data sheet

      Download (32.46k)

      HT356A63_manual.PDF

      Operating instructions

      Download (1.7M)