basic data | |||
sensitivity (±10%) | 50 mV / g | 5.1 mV/(m/s²) | |
range | ±100 g pk | ±981 m/s 2 pk | |
frequency range (±5%) | 6 … 5,000 Hz | ||
Frequency range (± 10%) | 5 … 5,000 Hz | ||
resonance frequency | ≥ 25,000 Hz | ||
wide band resolution | 0.0004 g RMS | 0.004 µm / s ² RMS | [3] |
linearity | ≤ 1% | [2] | |
transverse acceleration sensitivity | ≤ 5% | ||
conditions of use | |||
Overload limit (shock) | ±7. 000 g PK | ±68. 600 m/s² pk | |
Temperature range (operation) | -65 … 325 ° F | -54 … 163 ° C | |
Strain sensitivity (footprint) | 0.001 g/µε | 0.01 (m/s²)/µε | [3] |
specifications | |||
power supply | 24 … 30 V DC | ||
Constant power supply | 2 … 20 mA | ||
output impedance | ≤ 100 Ω | ||
Bias voltage | 7 … 16 V DC | [1] | |
discharging charging time constant | 0.08 … 0<5 s | ||
settlingbr(auf Bias-Spannung ±10 %) | < 3 s | ||
Spectral noise (1 Hz) | 130 µg / √ Hz | 1,275 (µm / s ²) / √ Hz | [3] |
spectral noise (10 Hz) | 30 µg / √ Hz | 294 ( µm / s ²) / √ Hz | [3] |
spectral noise (100 Hz) | 10 µg / √ Hz | 98.1 (µm / s ²) / √ Hz | [3] |
spectral noise ( 1,000 Hz) | 3 µg / √ Hz | 29.4 (µm / s ²) / √ Hz | [3] |
[2] | zero-based balancing line, determined using the method of least squares | ||
[3] | typically | ||
[4] | Details: see PCBs Declaration of conformance PS023 | ||
Equipment | |||
080A109 | mounting wax | -1 | |
080A12 | Adhesive mounting | -1 | |
080A90 | glue | -1 | |
081 B 05 | mounting bolts ( 10-32 on 10-32) | -1 | |
ACS-1 T | frequency response for Triaxial accelerometer, traceable to NIST, 10 Hz up to the upper 5% frequency | -1 | |
M081B05 | mounting bolts 10-32 to M6 x 0.75 | -1 | |
(T) TEDS memory in accordance with IEEE PP1451. 4 | |||
(TLA) TEDS LMS International - free format | |||
(TLB) TEDS LMS international - format for the automotive industry | |||
(TLC) TEDS LMS international - format for the aviation industry | |||
(TLD) TEDS memory in accordance with IEEE P1451. 4 | |||
Information | |||
features | versatile |