PCB-HT(M)354C03
basic data | |||
sensitivity (±10%) | 100 mV/g | 10.2 mV/(m/s²) | |
range | ±50 g pk | ±490 m/s 2 pk | |
frequency range (±5%) | 10 … 2,000 Hz | ||
Frequency range (± 10%) | 8 … 4,000 Hz | ||
frequency range (± 3 dB) | 5 … 6,000 Hz | ||
resonance frequency | ≥ 12,000 Hz | ||
wide band resolution | 0.0004 g RMS | 0.004 m/s² RMS | [1] |
linearity | ≤ 1% | [2] | |
transverse acceleration sensitivity | ≤ 5% | [3] | |
Conditions of use | |||
Overload limit (shock) | ±5. 000 g pk | ±49. 050 m/s² pk | |
Temperature range | 65… 325 ° F | -54 … 163 ° C | |
strain sensitivity (footprint) | 0.005 g/µε | 0.05 (m/s²)/µε | [1] |
Technical characteristics | |||
supply | 21 … 30 V DC | ||
constant power supply | 2 … 20 mA | ||
Output impedance | ≤ 300 Ω | ||
Bias voltage | 10 … 14,5 V DC | ||
Discharging charging time constant | 0.04 … 0.2 s | ||
settling time < br(auf Bias-Spannung ±10 %) | >12s | ||
Spectral noise (1 Hz) | 200 µg / √ Hz | 1.961 (µm / s ²) / √ Hz | [1] |
spectral noise (10 Hz) | 75 µg / √ Hz | 735 ( µm / s ²) / √ Hz | [1] |
spectral noise (100 Hz) | 20 µg / √ Hz | 196 (µm / s ²) / √ Hz | [1] |
spectral noise ( 1,000 Hz) | 8 µg / √ Hz | 79 (µm / s ²) / √ Hz | [1] |
electrical insulation (base) | ≥ 100 MΩ | ||
physical properties | |||
Sensor element | ceramic | ||
geometry of the sensor element | shear principle | ||
housing material | titanium | ||
Sealing | hermetically sealed welded | ||
size - hex | 0,815 in | 20.7 mm | |
Size - height | 0.45 in | 11.4 mm | |
Mass | 0.55 oz | 15.5 grams | [1] |
wiring | 1/4 "-28 4-pin | ||
" Connecting position | side | ||
mounting | hole | ||
notes | |||
[1] | typically | ||
[2] | zero-based balancing line, determined using the method of least squares | ||
[3] | transverse acceleration sensitivity typically≤ 3% | ||
[4] | details: see PCBs Declaration of conformance PS023 | ||
equipment | |||
039A23 | Inbusschlü wrench, 5/32 "hex | -1 | |
080A109 | mounting wax | -1 | |
081 B 60 | insulated Mounting screw, 10-32 thread x 5/8 "long (for model 354 C 02) | -1 | |
ACS-1 T | frequency response for Triaxial accelerometer, rückfü hrbar on NIST, 10 Hz up to the upper 5% frequency | -1 | |
(M) metric mounting | |||
equipment | |||
M039A23 | are üssel, 4 mm hex | -1 | |
M081B60 | metric mounting screw | -1 | |
additional information | |||
features | Earth free mounting with round screw |