PCB-W356A61/NC
basic data | |||
sensitivity (±15%) | 10 mV / g | 1.02 mV/(m/s²) | |
range | ±500 g pk | ±4. 905 m/s 2 pk | |
frequency range (-5%) | 2 … 4,000 Hz | ||
Resonance frequency | ≥55,000 Hz | ||
Edge steepness of the filter | 6 dB/octave | [1] | |
electric filter corner frequency | 15,000 Hz | [1] | |
Wide band resolution | 0.008 g RMS | 0.08 m/s² RMS | [1] |
Linearity error | ≤1% | [2] | |
transverse acceleration sensitivity | ≤5% | ||
conditions | |||
Overload limit (Shock) | ±10. 000 g pk | ±98.100 m/s² pk | |
Temperature range (Operation) | -65 … 325 ° F | -54 … 163 ° C | |
specifications | |||
power supply | 18 … 30 V DC | ||
Constant power supply | 2 … 20 mA | ||
output impedance | ≤200Ω | ||
Bias voltage | 7 … 11 V DC | ||
Discharging charging time constant | 0.3 … 1,0 s | ||
settling time < br(auf Bias-Spannung ±10 %) | ≤ 3.0 s | ||
Spectral noise (1 Hz) | 445 µg / √Hz | 4,365 (µm / s ²) / √Hz | [1] |
Spectral noise (10 Hz) | 135 µg / √Hz | 1,325 (µm / s ²) / √Hz | [1] |
spectral noise (100 Hz) | 90 µg / √Hz | 883 ( µm / s ²) / √ Hz | [1] |
spectral noise (1,000 Hz) | 80 µg / √Hz | 785 (µm / s ²) / √Hz | [1] |
physical properties | |||
5 in-lb | 45 … 56 NCM | ||
notes | |||
[1] | typically | ||
[2] | zero-based balancing line, determined with the method of least squares | ||
[3] | details: see PCBs Declaration of conformance PS023 | ||
equipment | |||
080A | Adhesive mounting | -1 | |
080A109 | mounting wax | -1 | |
081A27 | mounting bolts, 5-40 on 5-40 | -1 | |
081A90 | mounting bolts, 10-32 on 5-40 | -1 | |
ACS-1 T | frequency response for Triaxial accelerometer, traceable to NIST, 10 Hz up to the upper 5% frequency | -1 | |
M081A27 | metric mounting bolts, 5-40 M3 x 0.50 | -1 | |
information | |||
features | Water - and oil-dense integrated cable
|