PCB-HT356B21
| basic data | |||
| sensitivity (±10%) | 10 mV / g | 1.02 mV/(m/s²) | |
| range | ±500 g pk | ±4. 905 m/s 2 pk | |
| frequency (Y - and Z-axis) < br(≤5 %) | 2 … 10,000 Hz | ||
| Frequency range (X-axis) (±5%) | 2 … 7,000 Hz | ||
| resonance frequency | ≥ 55,000 Hz | ||
| Wide band resolution | 0,004 g RMS | 0.04 m/s² RMS | [2] |
| linearity error | ≤ 1% | [1] | |
| transverse acceleration sensitivity | ≤ 5% | ||
| conditions of use | |||
| Overload limit (shock) | ±10. 000 g pk | ±98.100 m/s² pk | |
| temperature range (operation) | -65 … 325 ° F | -54 … 163 ° C | |
| specifications | |||
| power supply | 18 … 30 V DC | ||
| Constant power supply | 2 … 20 mA | ||
| output impedance | ≤200Ω | ||
| Bias voltage | 7 … 11 V DC | ||
| Discharging charging time constant | 0.3 … 1,0 s | ||
| settlingbr(auf Bias-Spannung ±10 %) | < 3 s | ||
| Spectral noise (1 Hz) | 1,000 µg / √ Hz | 9.810 (µm / s ²) / √ Hz | [2] |
| spectral noise (10 Hz) | 300 µg / √ Hz | 2.943 ( µm / s ²) / √ Hz | [2] |
| spectral noise (100 Hz) | 100 µg / √ Hz | 981 (µm / s ²) / √ Hz | [2] |
| spectral noise ( 1,000 Hz) | 50 µg / √ Hz | 490 (µm / s ²) / √ Hz | [2] |
| physical properties | |||
| sensor element | ceramic | ||
| Geometry of the sensor element | Shear principle | ||
| Housing material | titanium | ||
| sealing | hermetically sealed | ||
| size e height | 0.4 in | 10.2 mm | |
| size - length | 0.4 in | 10.2 mm | |
| size - width | 0.4 in | 10.2 mm | |
| Weight | 0.14 oz | 4 grams | [2] |
| electrical connection | 8-36 4-Pin | ||
| Connector position | Side | ||
| mounting screw | 5-40 female | ||
| notes | |||
| [1] | zero-based balancing line, determined with the method the least squares | ||
| [2] | typically | ||
| [3] | details: see PCBs Declaration of conformance PS023 | ||
| Accessories | |||
| 034 K 10 | connection cable, length 3 m, Mini 4-pin connector to three BNC | -1 | |
| 080A | adhesive mounting | -1 | |
| 080A109 | mounting wax | -1 | |
| 081A27 | Mounting bolts, 5-40 on 5-40 | -1 | |
| 081A90 | mounting bolts, 10-32 on 5-40 | -1 | |
| ACS-1 T | Frequency response for Triaxial accelerometer, traceable to NIST, 10 Hz up to the upper 5% frequency | -1 | |
| M081A27 | metric mounting bolts, 5-40 M3 x 0.50 | -1 |