PCB-045000-02252
Load Cell, S-Type, 2500N 5000 Ohm M10 x 1 Thd
- Measurement Range: 562 lb (2500 N)
- Size - Height: 3.0 in (76.2 mm)
- Electrical Connector: 6 ft. Integrated Cable
Specification Notes
[1] FS - Full Scale.
[2] RO - Rated Output.
[3] Singularly applied, i.e. no other extraneous loads.
[4] Over compensated operating temperature range.
[5] Nominal.
[6] Calibrated at 10 VDC, usable 5 to 20 VDC or VAC RMS.
English: | SI: | ||
---|---|---|---|
Performance | |||
Measurement Range | 562 lb | 2500 N | [1] |
Sensitivity (±10 %) | 2 mV/V | 2 mV/V | [2] |
Non-Linearity | ≤0.15 % FS | ≤0.15 % FS | |
Hysteresis | ≤0.15 % FS | ≤0.15 % FS | |
Non-Repeatability | ≤0.05 %RO | ≤0.05 %RO | |
Creep (in 20 minutes) | ≤0.02 % | ≤0.02 % | |
Resonant Frequency | 2.2 kHz | 2.2 kHz | |
Environmental | |||
Overload Limit | 843 lb | 3750 N | |
Load Limit (Side Force, FX or FY) | 56.2 lb | 250 N | [3] |
Load Limit (Bending Moment, MX or MY) | 112.4 in-lb | 12.7 Nm | [3] |
Load Limit (Axial Torque, MZ) | 112.4 in-lb | 12.7 Nm | [3] |
Temperature Range (Operating) | 0 to +200 °F | -18 to +93 °C | |
Temperature Range (Compensated) | +75 to +150 °F | +21 to +65 °C | |
Temperature Effect on Output (Maximum) | ±0.002 %Reading/°F | ±0.0036 %Reading/°C | [4] |
Temperature Effect on Zero Balance (Maximum) | ±0.0015 %FS/°F | ±0.027 %FS/°C | [4] |
Electrical | |||
Bridge Resistance | 5000 Ohm | 5000 Ohm | [5] |
Excitation Voltage (Recommended) | 10 VDC | 10 VDC | [6] |
Insulation Resistance | >5000000000 Ohm | >5000000000 Ohm | |
Zero Balance | ≤1 % FS | ≤1 % FS | |
Output Polarity | + Tension | + Tension | |
Physical | |||
Size - Height | 3.0 in | 76.2 mm | |
Size - Width | 1.0 in | 25.4 mm | |
Size - Length | 2.0 in | 51.0 mm | |
Weight | 0.43 lb | 195 g | |
Housing Material | Aluminum | Aluminum | |
Sensing Element | Strain Gage | Strain Gage | |
Deflection at Full Scale Capacity | 0.0025 in | 0.05 mm | |
Electrical Connector | 6 ft. Integrated Cable | 6 ft. Integrated Cable | |
Electrical Connection Position | Side | Side |