PCB-023
Hardline, coax, 30 awg, mineral insulated cable (-300 to +1200 F) (price per foot) **Not field installable**
***Maximum cable length is 50ft (15m)***- Cable Style: Coaxial
- Number of Conductors: 1
- Cable Jacket Material: Stainless Steel
- Temperature Range: -300 to +1200 °F (-184 to +650 °C)
Specification Notes
[1] Typical.
| English: | SI: | ||
|---|---|---|---|
| Performance | |||
| Number of Conductors | 1 | 1 | |
| Cable Style | Coaxial | Coaxial | |
| Environmental | |||
| Temperature Range | -300 to +1200 °F | -184 to +650 °C | |
| Radiation Exposure Limit (Integrated Neutron Flux) | 1 E10 N/cm² | 1 E10 N/cm² | |
| Radiation Exposure Limit (Integrated Gamma Flux) | 1 E8 rad | 1 E8 rad | |
| Electrical | |||
| Capacitance (conductor to shield / drain @ 70 °F (21 °C)) | <130 pF/ft | <427 pF/m | |
| Insulation Resistance (@ 70 °F (21 °C)) | ≥1T Ohm | ≥1T Ohm | |
| Insulation Resistance (@900°F (482 °C)) | ≥100000000 Ohm | ≥100000000 Ohm | |
| Physical | |||
| Cable Jacket Diameter | .059 | 1.5 | [1] |
| Cable Jacket Material | Stainless Steel | Stainless Steel | |
| Conductor Style | Solid | Solid | |
| Conductor Material | Solid Nickel Wire | Solid Nickel Wire | |
| Conductor Diameter (30 AWG) | 0.010 | 0.24 | [1] |
| Insulation Material Over Conductor(s) | Magnesium Oxide | Magnesium Oxide | |
| Bend Radius (minimum) | 2 in | 50.8 mm | |
| Weight | .024 oz/ft | 2.23 gm/m | [1] |
* All specifications are at room temperature unless otherwise specified.