PCB-(M)623C01
basic data | |||
sensitivity (±5%) | 100 mV/g | 10.2 mV/(m/s²) | [5] |
measuring range | ±50 g | ±490 m / s² | |
Frequency range (±5%) | 144 … 480,000 cpm | 2.4 … 8,000 Hz | [2] |
frequency range (± 10%) | 102 … 600,000 cpm | 1.7 … 10,000 Hz | |
frequency range (± 3 dB) | 48 … 900,000 cpm | 0.8 … 15,000 Hz | |
resonance frequency | 2,400 kcpm | 40,000 Hz | [1] |
wide band resolution | 100 µg | 981 µm / s ² | [1] |
linearity | ≤1% | [3] | |
Transverse acceleration sensitivity | ≤ 5% | ||
conditions of use | |||
Overload limit (shock) | 5,000 g PK | 49,050 m/s² pk | |
temperature range | -65 … 250 ° F | -54 … 121 ° C | |
Protection class | IP68 | ||
technical Properties | |||
settling time (on bias voltage ± 1%) | ≤ 2.0 s | ||
discharging charging time constant | ≥ 0.2 s | ||
Supply voltage | 18 … 28 V DC | ||
constant power supply | 2 … 20 mA | ||
Output impedance | < 100 Ω | ||
Bias voltage | 8 … 12 V DC | ||
spectral noise (10 Hz) | 7.0 µg / √ Hz | 68.7 ( µm / s ²) / √ Hz | [1] |
spectral noise (100 Hz) | 2.8 µg / √ Hz | 27.5 (µm / s ²) / √ Hz | [1] |
spectral noise ( 1,000 Hz) | 0.9 µg / √ Hz | 8.8 (µm / s ²) / √ Hz | [1] |
electrical protection | RFI/ESD | ||
electrical insulation | ≥ 100 MΩ | ||
Physical properties | |||
size - Allen | 11/16 in | 17.5 mm | |
[6] | details: see PCBs Declaration of conformance PS023 and PS061 | ||
Accessories | |||
081A40 | mounting bolts with 1/4 "-28 thread | -1 | |
ICS-1 | frequency response for uniaxial sensors from 10 Hz up to the upper 5% frequency" | -1 | |
(M) metric mounting | |||
equipment | |||
M081A61 | metric mounting bolts with M6 threaded | -1 | |
(EX) with ATEX approval | |||
approval for use in potentially explosive atmospheres | EEx ia IIC T4,-54 ° C ≤ Ta ≤ 121 ° C, II 1 G | ||
(LB) low Bias voltage | |||
Bias voltage | 6 … 8 V DC | ||
power | 12 … 28 V DC | ||
Measuring range | ±35 g | ±343 m / | |
(CS) CSA-approved | |||
approval for use in potentially explosive atmospheres | CLI, div I, groups A, B, C, D CL II, div I, groups E, F, G Cl III, div I | ||
approval for use in potentially explosive atmospheres | ExIA IIC T4, AExia IIC, T4 | ||
Approval for use in potentially explosive atmospheres | CL I, div 2, groups A, B, C, D ExnL IIC T4, AExnA IIC T4 |