PCB-(M)234B
zoom_out_map

PCB-(M)234B

  • Force measuring element with charge output,
  • Range 35.6 … 111 kN,
  • Sensitivity 4.05 pC/N,
  • Upper frequency limit 8,000 Hz,
  • 10-32 female connector on the side
basic data
Sensitivity (± 15%) 18 pC / lb 4047 pC / kN
Measurement range (compression force) ≤25.000 lb ≤111,2 kN
Measurement range (tensile force) ≤8.000 lb ≤35,59 kN
Maximum static force (compression force) 30,000 lb 133.45 kN
Maximum static force (tensile force) 10,000 lb 44.48 kN
Upper limit frequency 8000 Hz [1] [2]
linearity error ≤1% FS [3]
Operating conditions
temperature range -100 ... 400 ° F -73 ... 204 ° C
Temperature coefficient of sensitivity ≤0,03% / ° F ≤0,054% / ° C
Technical characteristics
capacity ≤32 pF [4]
insulation resistance ?1.000.000 MΩ
physical properties
rigidity 6 lb / microinches 1.05 kN / micron [4]
Size - Diameter 1.34 in 34.04 mm
Size - Height 2.50 in 63.5 mm
Dimensions 8.7 oz 246 grams
housing material stainless steel
seal hermetically sealed
electrical connection 10-32 coaxial
port location Laterally
mounting thread 5 / 8-18 female No metric equivalent
Hints
[1] Assuming a value determined on the basis of solid-state dynamic calculations
[2] The lower limit frequency and system noise are dependent on the signal conditioning electronics.
[3] Zero-based line of best fit, determined by the method of least squares
[4] typically,
(M) Metric assembly
mounting thread no equivalent M16 x 1.50 Female
(P) Positive output polarity
(W) Waterproof cable connection
cable outlet Laterally
PCB-(M)234B