PCB-357A09/NC
basic data | |||
sensitivity (±20%) | 1.7 pC/g | 0.17 pC/(m/s²) | |
range | ±2. 000 g PK | ±19. 620 m/s² pk | |
frequency range (+ 5%) | ,10,000 Hz | [2] | |
Frequency range (+ 10%) | 13,000 Hz | [2] | |
resonance frequency | ≥ 50,000 Hz | ||
linearity | ≤ 1% | [4] | |
Transverse acceleration sensitivity | ≤ 5% | [3] | |
conditions | |||
(shock) overload limit | ± 10.000 g PK | ±98.100 m/s² pk | |
Temperature range | -100 … 350 ° F | -73 … 177 ° C | |
strain sensitivity (base area) | ≤ 0.10 g/µε | ≤ 1.0 (m/s²)/µε | [1] |
technical characteristics | |||
capacity | 310 pF | [1] | |
insulation resistance (at 21 ° C) | > 10,000 M Ω | ||
output polarity | negative | ||
Physical properties | |||
Sensor element | ceramic | ||
Geometry of the sensor element | shear principle | ||
housing material | titanium | ||
sealing | Epoxy resin | ||
size - height | 0.14 in | 3.6 mm | |
size - length | 0.45 in | 11.4 mm | |
Size - width | 0.25 in | 6.4 mm | |
mass | 0.02 oz | 0.6 grams | [1] |
wiring | 3-56 coaxial connector | ||
connection position | side | ||
attachment | bonding | ||
notes | |||
[1] | typically | ||
[2] | the lower cut-off frequency depends on the used signal conditioning electronicsfrom. | ||
[3] | transverse acceleration sensitivity typically ≤ 3% | ||
[4] | zero-based balancing line, determined with the method of least squares | ||
equipment | |||
039A27 | transfer tool for the models 352A21, 352 C-22, 352A25, 357A09, 357 C 10 / NC | -1 | |
080A109 | mounting wax | -1 | |
ACS-1 | frequency response, traceable to NIST (10 Hz up to the top 5% point) | -1 | |
(P) positive output voltage | |||