PCB-357A08/NC
| basic data | |||
| sensitivity (±20%) | 0.35 pC/g | 0.036 pC/(m/s²) | |
| range | ± 1.000 g PK | ±9. 800 m/s² pk | |
| Frequency range (+ 5%) | ,12,000 Hz | [2] | |
| frequency range (+ 10%) | ,20,000 Hz | [2] | |
| Resonance frequency | ≥ 70,000 Hz | ||
| linearity | ≤ 1% | [3] | |
| transverse acceleration sensitivity | ≤ 5% | ||
| Conditions of use | |||
| (shock) overload limit | ± 10.000 g pk | ±98.100 m/s² PK | |
| Temperature range | -100 … 350 ° F | -73 … 177 ° C | |
| technical | |||
| capacity | 140 pF | [1] | |
| Insulation resistance (at 21 ° C) | > 10,000 M Ω | ||
| Output polarity | negative | ||
| electrical insulation (base) | ≥100 MΩ | ||
| physical properties | |||
| sensor element | Ceramic | ||
| geometry of the sensor element | shear principle | ||
| housing material | aluminum | ||
| Waterproofing | epoxy resin | ||
| size - height | 0.11 in | 2.8 mm | |
| size - diameter | 0.16 in | 4.1 mm | |
| Size - width | 0.27 in | 6.9 mm | |
| mass | 0.006 oz | 0.16 grams | [1] |
| electric Connection | 3-56 coaxial plug | ||
| connection position | side | ||
| notes | |||
| [1] | typically | ||
| [2] | the lower cut-off frequency depends on the used signal conditioning electronics. | ||
| [3] | zero-based balancing line, determined with the methodthe least squares | ||
| equipment | |||
| 039A29 | transfer tool | -1 | |
| 080A109 | mounting wax | -1 | |
| ACS-1 | frequency response, traceable to NIST (10 Hz up to the upper 5% point) | -1 | |
| (P) positive output voltage | |||