PCB-3713E1110G
zoom_out_map

PCB-3713E1110G

  • Triaxial MEMS accelerometer,
  • Suitable for measuring static accelerations,
  • Measuring range 10 g,
  • Sensitivity200 mV / g,
  • Typical frequency range 0 … 1,000 Hz,
  • Supply voltage 6 … 30 V DC,
  • 9-pin female connector on the side
  • basic data
    sensitivity (±3%) 200 mV / g 20.4 mV/(m/s²) [1]
    range ±98, 1 m/s² pk ±10 g pk
    Frequency range (± 3 dB) 0 … 1,000 Hz [2]
    frequency range (± 3 dB) 0 … 500 Hz [5]
    Phase error < 10 °
    wide band resolution (0,5 … 100 Hz) [2] 0.002 m/s² rms rms 0.2 mg
    Linearity error ≤ 1% [3] [4]
    transverse acceleration sensitivity ≤ 5%
    conditions of use
    Overload limit (shock) ±5. 000 g pk ±49. 050 m / pk
    Temperature range (operation) -65 … 250 ° F -54 … 121 ° C
    temperature range (storage) -65 … 250 ° F -54 … 121 ° C
    Temperature coefficient of sensitivity ±3% [6]
    temperature coefficientzero ±2% FSO [6] [3]
    strain sensitivity (footprint) 0.001 g/µε 0.01 (m/s²)/µε [2]
    Magnetic sensitivity 100 µg/Gs/9.8 (m/s²) / T [2]
    technical specifications
    power supply 6 … 30 V DC
    Power ≤ 30 mA
    output impedance ≤ 120 Ω
    Spannungsoffset ±80 mV DC [7]
    spectral noise (1 … 100 Hz) 30 µg / √ Hz 294 (µm / s ²) / √ Hz [2]
    electrical insulation (base) ≥ 100 MΩ
    physical properties
    housing material titanium
    Sealing hermetically sealed
    size - length 0.85 in 21.6 mm
    Gr size - width 0.85in 21.6 mm
    size - height 0.85 in 21.6 mm
    weight 0.8 oz 22.7 grams
    Electrical connector 9-Pin
    Connection on the side
    mounting thread 10-32 female
    notes
    [1] measured @ 100 Hz
    [2] typically
    [3] FSO = "Full Scale Output": maximum output (4 V measuring range ( DC).
    [4] zero-based balancing line, determined using the method of least squares
    [5] guaranteed; through supplied with Calibration certificate is
    [6] -54 … 121 ° C, reference 24 ° C
    [7] offset at 3 meters cable length (type 037)
    [8] details: see PCB Declarationof conformance PS027
    equipment
    080A12 adhesive mounting -1
    081 B 05 Mounting bolts, 10-32 on 10-32 -1
    M081B05 mounting bolts, 10-32 to M6 x 0.75 -1
    ACS-145 T calibration of amplitude and phase response from 2 Hz to the upper ±3dB point (500 Hz) -1
    PCB-3713E1110G

    Specific References

    Download

    3713E1110G_drawing.PDF

    Technical drawing

    Download (1.09M)

    3713E1110G_manual.PDF

    Operating instructions

    Download (1.39M)

    3713E1110G_specs.PDF

    Technical data sheet

    Download (81.52k)