PCB-3713B1150G

PCB-3713B1150G

  • Triaxial MEMS accelerometer,
  • Suitable for measuring static accelerations,
  • Measurement range 50 g,
  • Sensitivity 40 mV / g,
  • Frequency range 0 … 1,000 Hz,
  • Supply voltage 6 … 30 V DC,
  • 9-pin female connector on the side
  • basic data
    sensitivity (±5%)40 mV / g4.1 mV/(m/s²)[1]
    range±50 g pk ±490, 5 m/s 2 pk
    frequency range (±5%)0 … 1,000 Hz
    Frequency range (± 10%)0 … 1,300 Hz
    resonance frequency≥ 5,100 Hz
    phase response (100 Hz)< 10 °
    wide band resolution6.0 mg rms0.059 m/s² RMS[2]
    Linearitä avoidable≤ 1%[3]
    transverse acceleration sensitivity≤ 3%
    conditions of use
    Overload limit (shock)±3. 000 g pk±29. 420 m/s² pk
    Temperature range (operation)-65 … 250 ° F-54 …121 ° C
    temperature range (storage)-65 … 250 ° F-54 … 121 ° C
    Temperature coefficient of sensitivity≤3%[4]
    Temperature coefficient of sensitivity the zero point±2% FSO[4] [5]
    strain sensitivity (base area)0.0001 g/µε0.001 (m/s²)/µε[2]
    magnetic sensitivity40µg/Gs/3.9 (m/s²) / T[2]
    technical characteristics
    Supply6 … 30 V DC
    power&le≤6 mA
    Output impedance≤ 100 Ω
    Spannungsoffset± 40 mV DC[6]
    spectral noise (1)600 µg /. √ Hz5,890 (µm / s ²) / √ Hz[2]
    electrical insulation (housing)≥ 100 MΩ
    physical properties
    Housing materialtitanium
    sealinghermetically sealed
    size - length0.8 in20.3 mm
    Size - width0.8 in20.3 mm
    size - height0.8 in20.3 mm
    Mass0.6 oz17.3 grams
    electrical connector9-Pin
    connection positionside
    Mounting thread10-32 female thread
    notes
    [1]measured at 100 Hz, 10 g RMS
    [2]typically
    [3]zero-based balancing line, determined using the method of least squares
    [4]-54 … 121 ° C, reference 24 ° C
    [5]FSO = "Full Scale Output": maximum output (4 V measuring range DC).
    [6]offset at 3 meters cable length (type 037)
    [7]details: see PCB Declaration of Conformance PS027
    Equipment
    080A12adhesive mounting-1
    081 B 05Mounting bolts (10-32 on 10-32)-1
    ACS-103Tcalibration of amplitude and phase response of 2 Hz up to the upper 5% frequency for Triaxial sensor-1
    M081B05Mounting bolts 10-32 to M6 x 0.75-1

    14 other articles of the same category: