PCB-3741B12200G

PCB-3741B12200G

  • MEMS accelerometer,
  • Suitable for measuring static accelerations,
  • Measuring range 200 g
  • Sensitivity 10 mV / g,
  • Frequency range 0 … 850 Hz,
  • Supply voltage 6 … 30 V DC,
  • Integrated cable, length 3 m,
    ending on stripped and tinned ends
  • basic data
    sensitivity (±5%)10 mV / g1.02 mV/(m/s²)[1]
     
    range±200 gpk±1. 961, 3 m/s 2 pk 
     
    frequency range (±5%)0 … 850 Hz  
     
    Frequency range (±10)0 … 1.250 Hz  
     
    resonance frequency> 11,000 Hz  
     
    phase shift (100 Hz)< 10 °  
     
    Wide band resolution21.1 mg rms0.21 m/s² RMS[2]
     
    linearity error≤ 1% FS [3]
     
    transverse acceleration sensitivity≤3%  
    conditions of use
    Overload limit (shock)±3. 000 g pk±29. 420 m/s² pk 
     
    temperature range (operation)-65 … 250 ° F-54.0 … 121 ° C 
     
    Temperature range (storage)-65 … 250 ° F-54.0 … 121 ° C 
     
    Temperature coefficient of sensitivity the zero point±2, 0% FSO [4] [5]
     
    strain sensitivity (footprint)0.0002 g/µε0.002 (m/s²)/µε[2]
    technical characteristics
    Supply voltage6 … 30 V DC  
     
    Power≤6 mA  
     
    output impedance≤100 Ω  
     
    Spannungsoffset± 40 mV DC [6]
     
    spectral noise (1)2,518 µg / √Hz24.693 (µm / s ²) / √Hz[2]
     
    electrical insulation (housing)? 100 M?? [7]
    physical properties
    housing materialanodized aluminum  
     
    waterproofingepoxy resin  
     
    Gr & ouml; ße - height0.30 in7.62 mm 
     
    size - length1.00 in25.4 mm 
     
    size - width0.85 in21.6 mm 
     
    Dimensions (without cable)0.35 oz9.92 grams[2]
     
    electrical connectionintegrated cable  
     
    Cable outletside  
     
    cable terminationtinned ends  
     
    cord typetype 010, 4-wire shielded cable  
     
    Cable length10 ft3 m 
     
    mountingtwo mounting holes  
    notes
    [1]Measured at 100 Hz, 10 g RMS  
     
    [2]typically  
     
    [3]Zero-balance just, determined using the method of least squares  
     
    [4]FSO = "Full Scale Output": maximum output (4 V measuring range (DC).  
     
    [5]-54 … 121 ° C, reference 24 ° C  
     
    [6]Offset tolerance for standard cable length (3 m)  
     
    [7]between housing/cable shielding and mounting surface or wire  
     
    [8]details: see PCB Declaration of Conformance PS027  
    Optional accessory
    080A208triaxial mounting cube-1 
    equipment
    081A103mounting screw2 
     
    ACS-103calibration of amplitude and phase response of 2 Hz up to the upper 5% frequency-1 
     
    M081A103mounting screw and Washer, threaded M3 x 0.52 