PCB-3711B1230G
    zoom_out_map

      PCB-3711B1230G

    • MEMS accelerometer,
    • Suitable for measuring static accelerations,
    • Measurement range 30 g,
    • Sensitivity 66.7 mV / g,
    • Frequency range 0 … 1,000 Hz,
    • Supply voltage 6 … 30 V DC,
    • Integrated cable, length 3 m,
      ending on stripped and tinned ends
    • of

      basic data
      sensitivity (±5%)66.7 mV / g6.80 mV/(m/s²) 
       
      range±30 g pk ±294, 2 m/s 2 pk 
       
      frequency range (±5%)0 … 1,000 Hz  
       
      Frequency range (± 10%)0 … 1500 Hz  
       
      resonance frequency≥4,000 Hz  
       
      phase response (100 Hz)< 10 °  
       
      wide band resolution3.5 mg rms0.034 m/s² RMS[3]
       
      Linearitä avoidable≤1% [2]
       
      transverse acceleration sensitivity≤3%  
      conditions of use
      Overload limit (shock)±3. 000 g pk±29. 420 m/s² pk 
       
      Temperature range (operation)-65 … 250 ° F-54 …121 ° C 
       
      temperature range (storage)-65 … 250 ° F-54 … 121 ° C 
       
      Temperature coefficient of sensitivity≤3% [1]
       
      Temperature coefficient of sensitivity the zero point±2% FSO [1] [4]
       
      strain sensitivity (base area)0.0002 g/µε0.002 (m/s²)/µε[3]
       
      magnetic sensitivity27.9µg/GS/2.8 (m/s²) / T[3]
      technical characteristics
      Supply6 … 30 V DC  
       
      power≤6 mA  
       
      Output impedance≤100 Ω  
       
      Spannungsoffset40 … 40 mV DC [5]
       
      spectral noise (1)330 µg / √Hz3.237 (µm / s ²) / √Hz[3]
       
      electrical insulation (housing)>100 MΩ  
      physical properties
      Housing materialTitanium  
       
      Sealedsealedclose  
       
      size - height0.45 in11.4 mm 
       
      size - length0.85 in21.6 mm 
       
      Size - width0.85 in21.6 mm 
       
      dimensions (with cable)2.74 oz77.8 g 
       
      electrical connectionIntegrated cable  
       
      Cable exitside  
       
      cable terminationtinned ends  
       
      cable typeType 010, 4-wire shielded cable  
       
      cable length10 ft3 m 
       
      mountinghole  
      Notes
      [1]-54 … 121 ° C, reference 24 ° C  
       
      [2]zero-based balancing line, determined using the method of least squares  
       
      [3]typically  
       
      [4]FSO = "Full Scale Output": maximum output signal of the measuring range (4 V )(DC).  
       
      [5]offset at 3 meters cable length (type 010)  
       
      [6]details: see PCB Declaration of Conformance PS027  
      Equipment
      080A152mounting clip-1 
       
      081A113mounting screw-2 
       
      ACS-103calibration of amplitude and phase response of 2 Hz up to the upper 5% frequency-1 
       
      M081A113metric mounting screw-2 
      PCB-3711B1230G

      Specific References

      Download

      3711B1230G_drawing.PDF

      Technical drawing

      Download (192.04k)

      3711B1230G_manual.PDF

      Operating instructions

      Download (786.97k)

      3711B1230G_specs.PDF

      Technical data sheet