PCB-3711B1230G
zoom_out_map

PCB-3711B1230G

  • MEMS accelerometer,
  • Suitable for measuring static accelerations,
  • Measurement range 30 g,
  • Sensitivity 66.7 mV / g,
  • Frequency range 0 … 1,000 Hz,
  • Supply voltage 6 … 30 V DC,
  • Integrated cable, length 3 m,
    ending on stripped and tinned ends
  • of

    basic data
    sensitivity (±5%) 66.7 mV / g 6.80 mV/(m/s²)  
     
    range ±30 g pk ±294, 2 m/s 2 pk  
     
    frequency range (±5%) 0 … 1,000 Hz    
     
    Frequency range (± 10%) 0 … 1500 Hz    
     
    resonance frequency ≥4,000 Hz    
     
    phase response (100 Hz) < 10 °    
     
    wide band resolution 3.5 mg rms 0.034 m/s² RMS [3]
     
    Linearitä avoidable ≤1%   [2]
     
    transverse acceleration sensitivity ≤3%    
    conditions of use
    Overload limit (shock) ±3. 000 g pk ±29. 420 m/s² pk  
     
    Temperature range (operation) -65 … 250 ° F -54 …121 ° C  
     
    temperature range (storage) -65 … 250 ° F -54 … 121 ° C  
     
    Temperature coefficient of sensitivity ≤3%   [1]
     
    Temperature coefficient of sensitivity the zero point ±2% FSO   [1] [4]
     
    strain sensitivity (base area) 0.0002 g/µε 0.002 (m/s²)/µε [3]
     
    magnetic sensitivity 27.9 µg/GS/2.8 (m/s²) / T [3]
    technical characteristics
    Supply 6 … 30 V DC    
     
    power ≤6 mA    
     
    Output impedance ≤100 Ω    
     
    Spannungsoffset 40 … 40 mV DC   [5]
     
    spectral noise (1) 330 µg / √Hz 3.237 (µm / s ²) / √Hz [3]
     
    electrical insulation (housing) >100 MΩ    
    physical properties
    Housing material Titanium    
     
    Sealed sealedclose    
     
    size - height 0.45 in 11.4 mm  
     
    size - length 0.85 in 21.6 mm  
     
    Size - width 0.85 in 21.6 mm  
     
    dimensions (with cable) 2.74 oz 77.8 g  
     
    electrical connection Integrated cable    
     
    Cable exit side    
     
    cable termination tinned ends    
     
    cable type Type 010, 4-wire shielded cable    
     
    cable length 10 ft 3 m  
     
    mounting hole    
    Notes
    [1] -54 … 121 ° C, reference 24 ° C    
     
    [2] zero-based balancing line, determined using the method of least squares    
     
    [3] typically    
     
    [4] FSO = "Full Scale Output": maximum output signal of the measuring range (4 V )(DC).    
     
    [5] offset at 3 meters cable length (type 010)    
     
    [6] details: see PCB Declaration of Conformance PS027    
    Equipment
    080A152 mounting clip -1  
     
    081A113 mounting screw -2  
     
    ACS-103 calibration of amplitude and phase response of 2 Hz up to the upper 5% frequency -1  
     
    M081A113 metric mounting screw -2  
    PCB-3711B1230G

    Specific References

    Download

    3711B1230G_drawing.PDF

    Technical drawing

    Download (192.04k)

    3711B1230G_manual.PDF

    Operating instructions

    Download (786.97k)

    3711B1230G_specs.PDF

    Technical data sheet

    Download (428.25k)