PCB-3711B12200G
| basic data | |||
| sensitivity (±10%) | 10 mV / g | 1.02 mV/(m/s²) | |
| range | ±200 gpk | ±1. 960 m/s² pk | |
| frequency range (±5%) | 0 … 850 Hz | ||
| Frequency range (± 10%) | 0 … 1.250 Hz | ||
| resonance frequency | ≥11,000 Hz | ||
| phase response (100 Hz) | < 10 ° | ||
| wide band resolution | 21.1 mg rms | 0.21 m/s² RMS | [3] |
| Linearitä avoidable | ≤1% | [2] | |
| transverse acceleration sensitivity | ≤3% | ||
| conditions of use | |||
| Overload limit (shock) | ±3. 000 g pk | ±29. 420 m/s² pk | |
| Temperature range (operation) | -65 … 250 ° F | -54 …121 ° C | |
| temperature range (storage) | -65 … 250 ° F | -54 … 121 ° C | |
| Temperature coefficient of sensitivity | ≤3% | [1] | |
| Temperature coefficient of sensitivity the zero point | ±2% FSO | [1] [4] | |
| strain sensitivity (base area) | 0.0005 g/µε | 0.005 (m/s²)/µε | [3] |
| magnetic sensitivity | 70 | µg/Gs/6.9 (m/s²) / T | [3] |
| technical characteristics | |||
| Supply | 6 … 30 V DC | ||
| power | ≤6 mA | ||
| Output impedance | ≤100 Ω | ||
| Spannungsoffset | ± 40 mV DC | [5] | |
| spectral noise (1) | 2,518 µg /. ? Hz | 24.693 (µm / s ²) / √Hz | [3] |
| electrical insulation (housing) | >100 MΩ | ||
| physical characteristicsn | |||
| housing material | titanium | ||
| sealing | hermetically sealed | ||
| size - height | 0.45 in | 11.4 mm | |
| size - length | 0.85 in | 21.6 mm | |
| size - width | 0.85 in | 21.6 mm | |
| Dimensions (with cable) | 2.29 oz | 65.0 grams | |
| electrical connection | integrated cable | ||
| cable outlet | Side | ||
| cable termination | tinned ends | ||
| cord type | type 010, 4-wire shielded cable | ||
| Cable length | 10 ft | 3 m | |
| mounting | hole | ||
| notes | |||
| [1] | -54 … 121 ° C,. Reference 24 ° C | ||
| [2] | zero-based balancing line, determined using the method of least squares | ||
| [3] | typically | ||
| [4] | FSO = "Full Scale Output": maximum output signal of the measuring range (4 V DC). | ||
| [5] | offset at 3 meters cable length (type 010) | ||
| [6] | details: see PCB Declaration of Conformance PS027 | ||
| Equipment | |||
| 080A152 | mounting clip | -1 | |
| 081A113 | mounting screw | -2 | |
| ACS-103 | calibration of amplitude and phase response of 2 Hz up to the upper 5% frequency | -1 | |
| M081A113 | metric mounting screw | -2 |