PCB-3711B1150G
zoom_out_map

PCB-3711B1150G

  • MEMS accelerometer,
  • Suitable for measuring static accelerations,
  • Measurement range 50 g,
  • Sensitivity 40 mV / g,
  • Frequency range 0 … 1,000 Hz,
  • Supply voltage 6 … 30 V DC,
  • 4-pin female connector on the side
  • basic data
    sensitivity (±5%) 40 mV / g 4.1 mV/(m/s²)  
     
    range ±50 g pk ±490 m/s 2 pk  
     
    frequency range (±5%) 0 … 1,000 Hz    
     
    Frequency range (± 10%) 0 … 1500 Hz    
     
    Resonance frequency ≥5,100 Hz    
     
    phase response (100 Hz) < 10 °    
     
    wide band resolution 6.0 mg rms 0.06 m/s² RMS [3]
     
    linearity ≤1%   [2]
     
    Transverse acceleration sensitivity ≤3%    
    conditions of use
    Overload limit (shock) ±3. 000 g pk ±29. 420 m/s² pk  
     
    temperature range (operation) -65 … 250 ° F -54 …121 ° C  
     
    temperature range (storage) -65 … 250 ° F -54 … 121 ° C  
     
    Temperature coefficient of sensitivity ≤3%   [1]
     
    Temperature coefficient of sensitivity the zero point ±2% FSO   [1] [4]
     
    strain sensitivity (base area) 0.0001 g/µε 0.001 (m/s²)/µε [3]
     
    magnetic sensitivity 40 µg/Gs/3.9 (m/s²) / T [3]
    technical characteristics
    Supply 6 … 30 V DC    
     
    power ≤6 mA    
     
    Output impedance ≤100 Ω    
     
    Spannungsoffset 40 … 40 mV DC   [5]
     
    spectral noise (1) 600 µg / √Hz 5,890 (µm / s ²) / √Hz [3]
     
    electrical insulation (housing) >100 MΩ    
    physical properties
    Housing material Titanium    
     
    Sealed sealedclose    
     
    size - height 0.45 in 11.4 mm  
     
    size - length 0.85 in 21.6 mm  
     
    Size - width 0.85 in 21.6 mm  
     
    mass 0.58 oz 16.3 grams  
     
    wiring 4-pin    
     
    Connection position side    
     
    mounting hole    
    notes
    [1] -54 … 121 ° C, reference 24 ° C    
     
    [2] zero-based balancing line, determined using the method of least squares    
     
    [3] typically    
     
    [4] FSO = "Full Scale Output": maximum output signal of the measuring range (4 V DC).    
     
    [5] offset at 3 meters cable length (type 010)    
     
    [6] details: see PCB Declarationof conformance PS027    
    equipment
    080A152 mounting clip -1  
     
    081A113 mounting screw 2  
     
    ACS-103 calibration of amplitude and phase response of 2 Hz up to the upper 5% frequency -1  
     
    M081A113 metric mounting screw 2  
    PCB-3711B1150G

    Specific References

    Download

    3711B1150G_drawing.PDF

    Technical drawing

    Download (1.18M)

    3711B1150G_manual.PDF

    Operating instructions

    Download (1.75M)

    3711B1150G_specs.PDF

    Technical data sheet

    Download (413.3k)