PCB-3713F1230G
zoom_out_map

PCB-3713F1230G

  • Triaxial MEMS accelerometer
  • Suitable for measuring static accelerations
  • Measuring range ± 30 g pk (± 294.2m / s²)
  • Sensitivity (± 3%) 45 mV / g (4.59mV / (m / s²))
  • Frequency range (± 5%) 0… 1,500 Hz
  • Supply voltage 5… 32 V DC
  • Integrated connection cable, length 3 meters,
    ending on stripped and tinned ends
Specifications
Basic dataEnglish unitsSI units 
Sensitivity (± 5%) 45 mV/g 4,59 mV/(m/s²) [1]
Measuring range ± 30 g pk ±294 m/s²pk
Frequency range (± 5%) 0… 1,500 Hz
Frequency range (± 10%) 0 ... 2,000 Hz
Resonance frequency ≥5,200 Hz
Phase response (100 Hz) <10 °
Broadband resolution 1 mg rms 0,01 m/s²RMS [2]
Linearity error ≤1% [3]
Lateral acceleration sensitivity ≤3%
Conditions of use
Overload limit (shock) ± 3,000 g pk ±29.420 m/s²pk
Temperature range (operation) -65 ... 250 ° F -54… 121 ° C
Temperature range (storage) -65 ... 250 ° F -54… 121 ° C
Temperature coefficient of sensitivity ± 2.5% [4]
Temperature coefficient of the zero point ± 1.5% FSO [4]
Stretch sensitivity (base area) 0.001 g / ml 0.01 (m / s²) / ε [2]
Magnetic sensitivity 40 µg/Gs 3,9 (m/s²)/T [2]
Technical characteristics
Supply voltage 5… 32 V DC
Power consumption ≤15 mA
Output impedance ≤120 Ω
Voltage offset ±20 mVDC [5]
Spectral Noise (1) 120 µg/√Hz 1.177 (µm / s²) / √Hz [2]
Electrical insulation (housing) >100 MΩ
Physical characteristics
Housing material titanium
seal Hermetically sealed
Size - length 0.8 in 20.3 mm
Size - width 0.8 in 20.3 mm
Size - height 0.8 in 20.3 mm
Ground (with cable) 4,2 oz 119 grams
Electrical connection Integrated cable
Cable outlet Laterally
Cable type Type 037, shielded 10-conductor cable
Cable length 10 ft 3 m

Hints
[1] Measured at 100 Hz, 10 g RMS
[2] Typically
[3] Zero-based best-fit line, determined using the least squares method
[4] -54… 121 ° C, reference 24 ° C
[5] Offset with 3 meter cable length (type 037)
[6] Details: see PCB Declaration of Conformance PS027

included supply
080A12 Adhesive fastening (1)
081B05 Mounting bolts (10-32 to 10-32) (1)
ACS-172T Calibration of the amplitude and phase response from 5 Hz to the upper ± 5% frequency range (1)
M081B05 Mounting bolts 10-32 on M6 x 0.75 (1)
PCB-3713F1230G

Specific References

Download

3713B1230G_drawing.PDF

Technical drawing

Download (316.17k)

3713B1230G_manual.PDF

Operating instructions

Download (975.45k)

3713B1230G_specs.PDF

Technical data sheet

Download (429.22k)