PCB-3713F122G
- Triaxial MEMS accelerometer
- Suitable for measuring static accelerations
- Measuring range ± 2 g pk (± 19.6m / s²)
- Sensitivity (± 3%) 675 mV / g (68.8mV / (m / s²))
- Frequency range (± 5%) 0 ... 250 Hz
- Supply voltage 5… 32 V DC
- Integrated connection cable, length 3 meters,
ending on stripped and tinned ends
| Specifications | |||
|---|---|---|---|
| Basic data | English units | SI units | |
| Sensitivity (± 5%) | 675 mV/g | 68,8 mV/(m/s²) | [1] |
| Measuring range | ± 2 g pk | ±19,6 m/s²pk | |
| Frequency range (± 5%) | 0 ... 250 Hz | ||
| Frequency range (± 10%) | 0 ... 350 Hz | ||
| Resonance frequency | ≥1,200 Hz | ||
| Phase response (10 Hz) | <2.5 ° | ||
| Broadband resolution | 0.1 mg rms | 0,001 m/s²RMS | [2] |
| Linearity error | ≤1% | [3] | |
| Lateral acceleration sensitivity | ≤3% | ||
| Conditions of use | |||
| Overload limit (shock) | ± 3,000 g pk | ±29.420 m/s²pk | |
| Temperature range (operation) | -65 ... 250 ° F | -54… 121 ° C | |
| Temperature range (storage) | -65 ... 250 ° F | -54… 121 ° C | |
| Temperature coefficient of sensitivity | ± 2.5% | [4] | |
| Temperature coefficient of the zero point | ± 1.5% FSO | [4] | |
| Stretch sensitivity (base area) | 0.001 g / ml | 0.01 (m / s²) / ε | [2] |
| Magnetic sensitivity | 200 µg/Gs | 19,6 (m/s²)/T | [2] |
| Technical characteristics | |||
| Supply voltage | 5… 32 V DC | ||
| Power consumption | ≤15 mA | ||
| Output impedance | ≤120 Ω | ||
| Voltage offset | ±20 mVDC | [5] | |
| Spectral Noise (1) | 10 µg/√Hz | 98.1 (µm / s²) / √Hz | [2] |
| Electrical insulation (housing) | >100 MΩ | ||
| Physical characteristics | |||
| Housing material | titanium | ||
| seal | Hermetically sealed | ||
| Size - length | 0.8 in | 20.3 mm | |
| Size - width | 0.8 in | 20.3 mm | |
| Size - height | 0.8 in | 20.3 mm | |
| Ground (with cable) | 4,2 oz | 119 grams | |
| Electrical connection | Integrated cable | ||
| Cable outlet | Laterally | ||
| Cable type | Type 037, shielded 10-conductor cable | ||
| Cable length | 10 ft | 3 m | |
| Hints | |||
|---|---|---|---|
| [1] | Measured at 5 Hz, 0.5 g RMS | ||
| [2] | Typically | ||
| [3] | Zero-based best-fit line, determined using the least squares method | ||
| [4] | -54… 121 ° C, reference 24 ° C | ||
| [5] | Offset with 3 meter cable length (type 037) | ||
| [6] | Details: see PCB Declaration of Conformance PS027 | ||
| included supply | ||
|---|---|---|
| 080A12 | Adhesive fastening | (1) |
| 081B05 | Mounting bolts (10-32 to 10-32) | (1) |
| ACS-85T | Calibration of the amplitude and phase response for triaxial transducers | (1) |
| M081B05 | Mounting bolts 10-32 on M6 x 0.75 | (1) |