TMS-9210D
- Portable system for calibration of vibration sensors
- Frequency range 0.7 ... 2,000 Hz
- adjustable amplitude
- LCD display in SI or US units
- Battery operation up to 18 hours
- Integrated ICP® supply and display of the bias voltage
- Signal input socket and output socket for reference signal
- Including data storage and USB port for data export
Specifications | |||
---|---|---|---|
Basic data | English units | SI units | |
Maximum amplitude - vibration acceleration | 2 g pk | 305 m/s²pk | |
Maximum amplitude - vibration speed | 12 in / sec pk | 305 mm/spk | |
Maximum amplitude - displacement | 200 mils pk-pk | 5 mm pk-pk | |
Maximum sensor mass | 800 grams | [1] | |
Frequency range | 42 … 120.000 cpm | 0.7 ... 2,000 Hz | |
Measurement uncertainties | |||
Vibration acceleration (2 ... 2,000 Hz) | ± 3% | [2] [7] | |
Vibration acceleration (0.7 ... 2,000 Hz) | ± 10% | [2] [7] | |
Vibration speed (3 ... 15 Hz) | ± 3% | [2] [7] | |
Vibration path (3 ... 15 Hz) | ± 3% | [3] | |
Vibration path (3 ... 150 Hz) | ± 2 dB | [3] | |
Amplitudenlinearität (100g Payload, 100Hz) | <1% | ||
Distortion (1… 5Hz) | Typically <15% | ||
Distortion (> 5… 20Hz) | Typically <10% | ||
Distortion (> 20… 2,000Hz) | Typically <7% | ||
Displayable units | |||
Vibration acceleration | gpk, gRMS, m/s²pk, m/s²RMS | ||
Vibration velocity | mm/spk, in/spk | ||
Oscillation path | mmpk-pk, milspk-pk | ||
frequency | Hz, CPM | ||
Test sensor sensitivity | mV, EU | [4] | |
Conditions of use | |||
Temperature range | 32 ... 122 ° F | 0 ... 50 ° C | |
Inputs / outputs | |||
Integrated ICP® supply | And | ||
Input for sensor to be tested | ICP, voltage | ||
Test of the bias voltage (for ICP® sensors) | And | ||
Indication of the sensitivity of the test object in the integrated display | And | ||
Input for external shaker excitation | Ja (1 VAC rms) | ||
Output of the reference sensor signal | Yes (100 mV / g) | ||
power supply | |||
Internal battery | 12 VDC, 4 Ah | ||
External supply | 110… 240 V, 50… 60 Hz | ||
Working time with battery (100 grams mass, 100 Hz, 1 g pk ) | 14 hours | [6] | |
Working time with battery (100 grams mass, 100 Hz, 10 g pk ) | 7 hours | [6] | |
Physical characteristics | |||
Size - height | 8.5 in | 22 cm | |
Size - width | 12 in | 30.5 cm | |
Size - depth | 10 in | 28 cm | |
Dimensions | 18 lb | 8.2 kg | |
Sensor mounting thread | 1/4 "-28 internal thread |
Hints | |||
---|---|---|---|
[1] | Amplitude and frequency range restricted with large sensor mass (see operating instructions) | ||
[2] | Measured with a reference sensor with a mass of 30 g | ||
[3] | Measured with a laser interferometer | ||
[4] | EU can be [g], [m / s2], [mm / s], [mils] or [µm] | ||
[5] | 5 mA constant current supply for ICP® and IEPE sensors | ||
[6] | In new condition | ||
[7] | Depending on the payload at higher frequencies, lateral movement can cause increased measurement uncertainty |