TMS-9210D
- Portable system for calibration of vibration sensors
- Frequency range 0.7 ... 2,000 Hz
- adjustable amplitude
- LCD display in SI or US units
- Battery operation up to 18 hours
- Integrated ICP® supply and display of the bias voltage
- Signal input socket and output socket for reference signal
- Including data storage and USB port for data export
| Specifications | |||
|---|---|---|---|
| Basic data | English units | SI units | |
| Maximum amplitude - vibration acceleration | 2 g pk | 305 m/s²pk | |
| Maximum amplitude - vibration speed | 12 in / sec pk | 305 mm/spk | |
| Maximum amplitude - displacement | 200 mils pk-pk | 5 mm pk-pk | |
| Maximum sensor mass | 800 grams | [1] | |
| Frequency range | 42 … 120.000 cpm | 0.7 ... 2,000 Hz | |
| Measurement uncertainties | |||
| Vibration acceleration (2 ... 2,000 Hz) | ± 3% | [2] [7] | |
| Vibration acceleration (0.7 ... 2,000 Hz) | ± 10% | [2] [7] | |
| Vibration speed (3 ... 15 Hz) | ± 3% | [2] [7] | |
| Vibration path (3 ... 15 Hz) | ± 3% | [3] | |
| Vibration path (3 ... 150 Hz) | ± 2 dB | [3] | |
| Amplitudenlinearität (100g Payload, 100Hz) | <1% | ||
| Distortion (1… 5Hz) | Typically <15% | ||
| Distortion (> 5… 20Hz) | Typically <10% | ||
| Distortion (> 20… 2,000Hz) | Typically <7% | ||
| Displayable units | |||
| Vibration acceleration | gpk, gRMS, m/s²pk, m/s²RMS | ||
| Vibration velocity | mm/spk, in/spk | ||
| Oscillation path | mmpk-pk, milspk-pk | ||
| frequency | Hz, CPM | ||
| Test sensor sensitivity | mV, EU | [4] | |
| Conditions of use | |||
| Temperature range | 32 ... 122 ° F | 0 ... 50 ° C | |
| Inputs / outputs | |||
| Integrated ICP® supply | And | ||
| Input for sensor to be tested | ICP, voltage | ||
| Test of the bias voltage (for ICP® sensors) | And | ||
| Indication of the sensitivity of the test object in the integrated display | And | ||
| Input for external shaker excitation | Ja (1 VAC rms) | ||
| Output of the reference sensor signal | Yes (100 mV / g) | ||
| power supply | |||
| Internal battery | 12 VDC, 4 Ah | ||
| External supply | 110… 240 V, 50… 60 Hz | ||
| Working time with battery (100 grams mass, 100 Hz, 1 g pk ) | 14 hours | [6] | |
| Working time with battery (100 grams mass, 100 Hz, 10 g pk ) | 7 hours | [6] | |
| Physical characteristics | |||
| Size - height | 8.5 in | 22 cm | |
| Size - width | 12 in | 30.5 cm | |
| Size - depth | 10 in | 28 cm | |
| Dimensions | 18 lb | 8.2 kg | |
| Sensor mounting thread | 1/4 "-28 internal thread | ||
| Hints | |||
|---|---|---|---|
| [1] | Amplitude and frequency range restricted with large sensor mass (see operating instructions) | ||
| [2] | Measured with a reference sensor with a mass of 30 g | ||
| [3] | Measured with a laser interferometer | ||
| [4] | EU can be [g], [m / s2], [mm / s], [mils] or [µm] | ||
| [5] | 5 mA constant current supply for ICP® and IEPE sensors | ||
| [6] | In new condition | ||
| [7] | Depending on the payload at higher frequencies, lateral movement can cause increased measurement uncertainty | ||