PCB-356A67
zoom_out_map

PCB-356A67

  • Triaxial ICP® vibration sensor,
  • With built-in low-pass filter,
  • Measuring range 500 g
  • Sensitivity 10 mV / g,
  • Frequency range 0.5 … 2,500 Hz,
  • 4-pin female connector on the side
  • of
    basic data
    sensitivity (±10%) 10 mV / g 1.02 mV/(m/s²)
    range ±500 g pk ±4. 900 m/s² pk
    frequency (Y - and Z-axis) (-5%) 0.5 … 2,500 Hz [2]
    Frequency range (X-axis) (-5%) 0,5 … 3,000 Hz [2]
    resonance frequency ≥ 25,000 Hz
    integrated Filter first order
    edge steepness of the filter 6 dB/octave
    electric filter corner frequency10,000 Hz [3]
    wide band resolution 0.0005 g RMS 0.005 m/s² RMS [1]
    Linearity error (400 g, 3.920 m/s²) ≤ 1% [3]
    linearity error (500 g, 4,900 m/s²) ≤ 2% [3]
    Transverse acceleration sensitivity ≤ 5%
    Conditions of use
    Overload limit (shock) ±7. 000 g pk ±68. 600 m/s² PK
    Temperature range (operation) -65 … 250 ° F -54 … 121 ° C
    strain sensitivity (base area) 0.001 g/µε 0.01 (m/s²)/µε [1]
    specifications
    power supply 20 … 30 V DC
    Constant power supply 2 … 20 mA
    output impedance ≤200Ω
    Bias voltage 8 … 12 V DC
    discharging charging time constant 1.0 … 2.0 s
    Settling time < br(auf Bias-Spannung ±10 %) <5 s
    spectral noise (1 Hz) 150 µg / √ Hz 1,472 (µm / s ²) / √ Hz [1]
    Spectral noise (10 Hz) 25 µg / √ Hz 245 (µm / s ²) / √ Hz [1]
    Spectral noise (100 Hz) 10 µg / √ Hz 98 (µm / s ²) / √ Hz [1]
    spectral noise (1,000 Hz) 5 µg / √ Hz 49 ( µm / s ²) / √ Hz [1]
    physical properties
    sensor element ceramic
    geometry of the sensor element shear principle
    Housing material titanium
    sealing hermetically sealed
    size e height 0.55 in 14.0 mm
    size - length 0.80 in 20.3 mm
    size - width 0.55 in 14.0 mm
    mass 0.37 oz 10.5 grams [1]
    wiring 1/4 "-28 4-pin
    " Connecting position side
    mounting thread 10-32 female thread
    Assembly torque 10 … 20 in-lb 113 … 225 NCM
    notes
    [1] typically
    [2] The upper cut-off frequency tolerance: ±500 Hz
    [3] zero-based balancing line, determined using the method of least squares
    [4] Details: see PCBs Declaration of conformance PS023
    Equipment
    080A109 mounting wax -1
    080A12 Adhesive mounting -1
    081 B 05 mounting bolts (10-32 on 10-32) -1
    ACS-1 T Frequency response for Triaxial accelerometer, traceable to NIST, 10 Hz up to the upper 5% frequency -1
    M081B05 mounting bolts 10-32 to M6 x 0.75 -1
    PCB-356A67

    Specific References

    Download

    356A67_drawing.PDF

    Technical drawing

    Download (41.9k)

    356A67_manual.PDF

    Operating instructions

    Download (1.74M)

    356A67_specs.PDF

    Technical data sheet

    Download (84.34k)