PCB-130F22
zoom_out_map

PCB-130F22

  • ICP® array free field microphone,
  • with TEDS 1.0,
  • diameter 7 mm,
  • sensitivity 45 mV / PA,
  • dynamic range > 122 dB,
  • frequency range 10... 20,000 Hz,
  • SMB connector
</ tbody >
specifications
basic dataEnglish unitsSI units 
Nominal microphone diameter 1/4 "  
application free-field  
(±2 dB) frequency range 20... 10,000 Hz  
frequency range (± 3 dB) 10... 16,000 Hz  
frequency range (±4 dB) 10... 20,000 Hz  
phase matching
(100 ... 3,000 Hz)
±3 ° [1] [2]
phase matching
(50 ... 5,000 Hz)
±5 ° [2]
phase matching
(5.000 ... 10,000 Hz)
±10 ° [2]
sensitivity (at 250 Hz) 45 mV / PA  
sensitivity (at 250 Hz) (±3 dB) -26.9 dB in relation to 1 V / PA  
Noise (linear) [2] 29 dB in relation to 20 µPa
Noise (A-weighted) < 26 dB(A) in relation to 20 µPa  
noise (A-weighted) 24 dB(A) in relation to 20 µPa [2]
dynamic range (for THD ≤3%) > 122 dB in relation to 20 µPa  
TEDS Chip integrated by default [3]
conditions of use
temperature range (operation) 14... 122 ° F 10... 50 ° C  
influence of temperature on the output signal (10...) 50 ° C) 0.7 dB [2]
specifications
power supply 18... 30 V DC  
constant power supply 2... 20 mA  
Bias voltage 5.5... 14 V DC  
output impedance <150 Ω  
physical properties
housing material stainless steel  
Electrical connection SMB coaxial socket  
size - diameter (total) 0.28 in 7 mm  
size - length (total) 2.32 in 59.0 mm  
Size 0.30 oz 8.5 grams [2]
Notes
[1] Typically ±3 ° in the range 100... 3,000 Hz    
[2] Typically    
[3] TEDS memory in accordance with IEEE P1451. 4    
       
Included accessories
ACS-21 Calibration of an electret microphone (1)
PCB-130F22

Specific References

Download

PCB 130F20_drawing

PCB 130F20_drawing

Download (80.81k)

PCB 130F22_manual

PCB 130F22_manual

Download (788.2k)

PCB 130F22_specs

PCB 130F22_specs

Download (30.28k)