PCB-HT426E01
    zoom_out_map

      PCB-HT426E01

    • ICP® preamplifiers for 1/2 "-microphones,
    • Operating temperature up to 120 ° C,
    • Gain - 0.06 dB,
    • Frequency range 1.6 … 126,000 Hz,
    • Incl. TEDS memory chip
    • basic data
      Nominal diameter of microphone1/2 "
      reinforcement (rel. 1,000 Hz)-0,06 dB[1] [2]
      Frequency range (±0. 1 dB) (rel. 1,000 Hz)6.3 … 126,000 Hz[4] [1]
      frequency range (-3 dB) (rel. 1,000 Hz)< 1.58 Hz[4] [1]
      Frequency range (±0. 1 dB) (rel. 1,000 Hz)10 … 126,000 Hz[5] [1]
      frequency range with phase deviation-1 … 1 °63 … 40,000 Hz[1]
      frequency range with phase deviation-1 … 10 °10 … 63 Hz[1]
      electrical noise (at 22 ° C) (A-weighted) ≤ 4.9 microvolts[1]
      electrical noise (at 22 ° C) (A-weighted)3.1 MV[1] [2]
      electrical noise (at 22 ° C) ( unweighted, 20 … 20,000 Hz)≤ 13.4 µV[1]
      electrical noise (at 22 ° C) (unweighted, 20 … 20,000 Hz)9.3 µV[1] [2]
      Electrical noise (at 120 ° C) (A-weighted)≤ 9.6 µV[1]
      electrical noise (at 120 ° C) (A-weighted)6.4 µV[1] [2]
      Electrical noise (at 120 ° C) (unweighted, 20 … 20,000 Hz)≤ 37.1 µV[1]
      electrical noise (at 120 ° C) (unweighted, 20 … 20,000 Hz)24.7 µV[1] [2]
      distortion (input 3 V rms at 1,000 Hz)≤ 70 dB[1]
      rate of change of the output2 V / µS[2]
      TEDS Chipintegrated by default[3]
      conditions
      temperature range (operation)-40 … 248 ° F-40 … 120 ° C
      influence of temperature±0. 1 dB[6]
      air humidity (non-condensing)0 … 95% RH
      influence by humidity±0, 1 dB[6]
      specifications
      power supply20 … 32 V DC
      Constant power supply2 … 10 mA
      impedance (input)9.4 G Ω[2]
      capacity (input)0.06 pF[2]
      Bias voltage10 … 14 V DC
      impedance (output)< 55 Ω
      Output range (maximum)±7 V pk
      physical properties
      parts usematerialstainless steel
      size - diameter0.5 in13 mm
      size - length3.5 in89 mm
      Mass1.45 oz41 g[2]
      electrical connectionBNC Jack
      thread f for microphone0,461 "-60 UNS11,7 mm - 60 UNS
      notes
      [1]measured with a reference microphone with12 pF
      [2]typically
      [3]TEDS memory in accordance with IEEE PP1451. 4
      [4]at 22 ° C
      [5]at 120 ° C
      [6]maximum
      [7]details: see PCB Declaration of Conformance PS065
      Accessories
      ERC-16calibration of a microphone preamplifier-1
      PCB-HT426E01

      Specific References

      Download

      HT426E01_drawing.PDF

      Technical drawing

      Download (310.68k)

      HT426E01_manual.PDF

      Operating instructions

      Download (677.9k)

      HT426E01_specs.PDF

      Technical data sheet

      Download (29.88k)