PCB-HT378C20
    zoom_out_map

      PCB-HT378C20

    • 1/2 "-ICP® precision microphone for diffuse field applications,
    • Combination of microphone capsule 377 B 20 and pre HT426E01,
    • Operating temperature up to 120 ° C,
    • Sensitivity 50 mV / PA,
    • Dynamic range > 137 dB,
    • Frequency range 3.5 … 16,000 Hz,
    • BNC connector,
    • As system calibrated
    • basic data
      Nominal diameter of microphone1/2 "  
       
      applicationdiffuse-field  
       
      Sensitivity50 mV / PA [2]
       
      sensitivity (±1. 5 dB)-26 dB in relation to 1 V / PA [2]
       
      frequency range (± 1 dB)6 … 6,300 Hz  
       
      (±2 dB) frequency range3.5 … 16,000 Hz  
       
      lower limiting frequency (-3 dB)1.0 … 2.75 Hz  
       
      Noise< 32 dB in relation to 20 µPa  
       
      noise< 17 dB(A) in relation to 20 µPa  
       
      Dynamic range> 137 dB in relation to 20 µPa  
       
      TEDS Chipintegrated by default [1]
      conditions of use
      Temperature range (operation)-40 … 257 ° F-40 … 125 ° C[3]
       
      Temperature coefficient of sensitivity0,005 dB/°F0.009 dB / ° C[2] [4]
       
      Influence of static pressure-0.01 dB/kPa [2] [4]
       
      Humidity coefficient of sensitivity±0, 001 dB/% RH [2]
       
      Influence by axial vibration63 dB in relation to 20 µPa [4]
      technical characteristics
      polarization voltage0 V [5]
       
      Supply20 … 32 V DC  
       
      constant power supply2 … 10 mA  
       
      Bias voltage10 … 14 V DC  
       
      maximum output rangeV ±7 PK  
       
      Output impedance< 55 ?  
      physical properties
      housing materialstainless steel alloy  
       
      Pressureback [6]
       
      electrical connectionBNC Jack  
       
      mounting thread(Amp)0,5 - 60 UNS  
       
      Size - diameter (with cap)0.52 in13.2 mm 
       
      size - diameter (without protection cap)0.50 in12.7 mm 
       
      size - height (with cap)3.88 in98.6 mm 
       
      size - height (without protection cap)3.84 in97.5 mm 
       
      mass1.74 oz49.2 grams[4]
      hints
      [1]TEDS memory in accordance with IEEE PP1451. 4  
       
      [2]based on 250 Hz  
       
      [3]maximum 120 ° C at constant current > 4 mA  
       
      [4]typically  
       
      [5]Prepolarized  
       
      [6]pressure compensation by the pre  
       
      [7]Details: see PCBs Declaration of conformance PS064  
      Equipment
      ACS-42calibration of a microphone with pre-amplifier-1 
      (TLD) TEDS memory in accordance with IEEE P1451. 4
      Accessories   
       
      ACS-63calibration microphone with pre-amplifier-1 
      PCB-HT378C20

      Specific References

      Download

      HT378C20_drawing.PDF

      Technical drawing

      Download (311.39k)

      HT378C20_manual.PDF

      Operating instructions

      Download (773.75k)

      HT378C20_specs.PDF

      Technical data sheet

      Download (32.96k)