PCB-TLD355M102

PCB-TLD355M102

  • ICP®-Vibrationssensor, 
  • With through hole, 
  • Ionizer with ground insulation, 
  • Ground isolated, 
  • Measuring range 500 g, 
  • Sensitivity 10 mV / g, 
  • Frequency range 1 ... 7,000 Hz, 
  • 10-32 connector on the side

specifications
basic dataEnglish unitsSI units 
Sensitivity (± 10%)10 mV/g1,02 mV/(m/s²)
measuring range± 500 g pk±4900 m/s²pk
Frequency range (± 5%)1 … 7.000 Hz
Frequency range (± 10%)0,6 … 10.000 Hz
Frequency range (± 3 dB)0,35 … 17.000 Hz
Filter type (low pass)einpolig
Corner frequency of the electric filter≥17.000 Hz
resonant frequency≥35.000 Hz
Broadband resolution0,001 gRMS0,01 m/s²RMS[3]
linearity error≤1 %[1]
Lateral acceleration sensitivity≤5 %[2]
Operating conditions
Overload limit± 5,000 g pk±49.050 m/s²pk
temperature range-65 … 325 °F-54 … 163 °C
Strain sensitivity (base area)0.05 g / min0.49 (m / s²) / me[3]
Technical characteristics
supply voltage19 … 30 VDC
Constant current supply2… 20 mA
output impedance≤1.00 Ω
Bias voltage8 … 12 VDC
discharging0,5 … 2,0 s
Spectral noise (1 Hz)440 µg/√Hz4320 (µm/s²)/√Hz[3]
Spectral noise (10 Hz)135 µg/√Hz1325 (µm/s²)/√Hz[3]
Spectral noise (100 Hz)35 µg/√Hz345 (µm/s²)/√Hz[3]
Spectral noise (1000 Hz)10 µg/√Hz98 (µm/s²)/√Hz[3]
Electrical insulation (base)>10¸ MΩ
Physical properties
Size - height0,40 in10,2 mm
Size - length0,70 in17,8 mm
Size - width0,63 in15,9 mm
Mass0,29 oz8.2 grams[3]
sensor elementQuartz
Geometry of the sensor elementScherprinzip
housing materialTitan
sealHermetically sealed
Electrical connection10-32 coaxial
port locationLaterally
attachmentThrough Hole

[4]

Hints
[1]Zero-based balancing line, determined by the least squares method
[2]Lateral acceleration sensitivity typically ≤ 3%
[3]typically,
[4]Details: siehe PCB Declaration of Conformance PS023

6 other articles of the same category: