PCB-(M)261A02

PCB-(M)261A02

  • Triaxial ICP® power measurement element
  • Measuring range (Z axis) 4.45 kN,
  • Measuring range (X - and Y-axes) 4.45 kN,
  • Sensitivity (Z-axis) 0.56 mV / N,
  • Sensitivity (X - and Y-axes) 1.12 mV / N,
  • Frequency range (Z axis) 0.01 … 10,000 Hz,
  • Frequency range (X - and Y-axes) 0.001 … 10,000 Hz,
  • 4-pin female connector on the side
  • of

    basic data
    sensitivity (Z axis) (±20%)2.5 mV / Nlb/0.56 mV / N[2]
     
    sensitivity (X - and Y-axes) (±20%)5 mV / lb1.12 mV/N[2]
     
    measuring range (Z axis)1,000 lb4.45 kN 
     
    measuring range (X - and Y-axes)1,000 lb4.45 kN 
     
    Maximum power (Z axis)1,320 lb5.87 kN 
     
    maximum force (X - and Y-axes)1,000 lb4.45 kN 
     
    maximum moment (Z axis)40 ft-lb54,23 Nm 
     
    maximum moment (X - and Y-axes)70 ft-lb94,91 Nm 
     
    wide band resolution (X - and Y-axes)0.006 lb RMS0.027 N RMS[1]
     
    Wide band resolution (X - and Y-axes)0.006 lb RMS0.027 N RMS[1]
     
    Upper cut-off frequency10,000 Hz  
     
    lower limiting frequency(Z axis) (-5%)0.01 Hz  
     
    Lower limiting frequency (X - and Y-axes) (-5%)0.001 Hz  
     
    linearity≤ 1% FS [3]
     
    Crosstalk (between X - and Y-axis)±3%  
     
    crosstalk (between X and y axis and Z axis)≤5%  
    Conditions of use
    temperature range-65 … 250 ° F-54 … 121 ° C 
    technical characteristics
    maximum output signal (Z axis)± 2.5 V DC  
     
    maximum output signal (X - and Y-axes)±5 V DC  
     
    Discharging charging time constant (Z axis)≥ 50 s  
     
    discharging charging time constant (X - and Y-axes)≥ 500 s  
     
    Supply voltage (all axes)20 … 30 V DC  
     
    constant power supply (all axes)2 … 20 mA  
     
    Output impedance≤100 Ω  
     
    Bias voltage8 … 14 V DC  
     
    Output polaritypositive  
    physical properties
    stiffness (Z axis)19 lb/µin3.3 kN/µm[1]
     
    Rigidity (X - and Y-axes)6 lb/µin1 kN/µm[1]
     
    mass34.40 oz975 grams 
     
    go äusematerialstainless steel  
     
    sealinghermetically sealed  
     
    electrical connection4-Pin  
     
    Connection positionside  
    notes
    [1]typically  
     
    [2]when using the recommended preload. The sensitivities can depending on the preload to ±5% change.  
     
    [3]zero-based balancing line, determined using the method of least squares  
     
    [4]Details: see PCBs Declaration of conformance PS023  
    (W) waterproof cable connection
    Cable outletOn the side  

    5 other articles of the same category: