PCB-(M)221B01

PCB-(M)221B01

  • ICP® force measuring element,
  • Measuring range 44.5 N,
  • Sensitivity 112 mV / N,
  • Frequency range 0.01 … 15,000 Hz,
  • 10-32 female connector on the side
  • basic data
    sensitivity (±15%)/500 mV / lb112.404 mV / kN
    measuring range (pressure)10 lb0,04448 kN
    Measuring range (traction)10 lb0,04448 kN
    maximum permissible static load (force)60 lb0,2669 kN
    maximum static force (traction)60 lb0,2669 kN
    wide band resolution0,0002 lb RMS0,0008896 N RMS[1]
    Lower limiting frequency (-5%)0.01 Hz[2]
    upper frequency limit15,000 Hz[4]
    linearity error≤ 1% FS[3]
    conditions
    temperature range-65 … 250 ° F-54 … 121 ° C
    temperature coefficient Temperature coefficient of sensitivity≤ 0.03 %/°F≤ 0,054 %/°C
    technical properties
    discharge charge time constant (at room temperature)≥ 50 s
    Supply20 … 30 V DC
    constant power supply2 … 20 mA
    Output impedance≤ 100 Ω
    Bias voltage8 … 14 V DC
    (Pressure) output polaritypositive
    physical properties
    stiffness2 lb/µin0.35 kN/µm[] 1]
    size - diameter0.65 in16.51 mm
    size - height1.25 in31.75 mm
    Mass1.1 oz31 grams
    Housing materialstainless steel
    sealinghermetically sealed
    electric Connection10-32-coaxial socket
    connection positionside
    mounting thread1/4 "-28 threaded" NoEquivalent
    notes
    [1]typically
    [2]calculated using the discharge load time constant
    [3]zero-based balancing line, determined using the method of least squares
    [4]assume that value determined on the basis of solid state Dynamics calculations
    [5]details: see PCBs Declaration of conformance PS023
    (M) metric mounting
    (N) negative output polarity
    (W) waterproof cable connection
    electrical connectionsealed cable connection
    Cable exitside

    29 other articles of the same category: