PCB-(M)350C04

PCB-(M)350C04

  • ICP® shock acceleration sensor,
  • With electric and mechanical filter,
  • Measuring range 5,000 g,
  • Sensitivity 1 mV / g,
  • Frequency range 0.4 … 10,000 Hz,
  • 10-32 female connector above
  • basic data
    sensitivity (±30%)1.0 mV / g0.10 mV/(m/s²) 
     
    range±5. 000 g pk±49. 000 m / pk 
     
    Frequency range (± 1 dB)0.4 … 10,000 Hz  
     
    frequency range (-3 dB)0.2 … 25,000 Hz [4]
     
    Corner frequency of the electrical filter (-3 dB)21,000 Hz [2] [1]
     
    resonance frequency of the mechanical filter35,000 Hz [3] [1]
     
    Resonance frequency≥ 100,000 Hz  
     
    wide band resolution (1 … 10,000 Hz)0.20 m/s² rmsrms 0.02 g[1]
     
    Linearity error≤ 2.0%  
     
    transverse acceleration sensitivity≤ 7%  
    conditions
    Overload limit (Shock)±50. 000 g pk±490. 000 m / pk 
     
    temperature range (operation)0 … 150 ° F-18 … 66 ° C 
     
    Temperature range(Storage)-40 …200 °F-40 … 93 ° C 
     
    Temperature influenceSee graph %/°F  
     
    strain sensitivity (footprint)0,002 g/µε0.02 (m/s²) /µε[1]
    specifications
    power supply20 … 30 V DC  
     
    Constant power supply2 … 20 mA  
     
    Output impedance≤200Ω  
     
    Bias voltage8 … 14 V DC  
     
    Discharging charging time constant1.0 … 2.0 s [1]
     
    settling time (area within ±10% of the bias voltage)< 10 s  
    Physical properties
    sensor elementceramic  
     
    geometry of the sensor elementshear principle  
     
    Housing materialtitanium  
     
    sealinghermetic  
     
    Size - hex0.375 in9.5 mm 
     
    size - height1.15 in29.2 mm 
     
    Mass0.19 oz5.4 grams[1]
     
    Electrical connection10-32-coaxial socket  
     
    connectiontop  
     
    mounting thread1/4 '28 External thread  
    notes
    [1]typically  
     
    [2]second-order low-pass filter  
     
    [3]the amplitude is increased in the resonance frequency by 9 dB.  
     
    [4]the specified upper limit frequency is a guideline. The frequency response is limited by the combination of electric and mechanical low pass filter.  
     
    [5]details: see PCBs Declaration of conformance PS023  
    Accessories
    ACS-14Hopkinson bar calibration f for shock sensor-1 
     
    ACS-22frequency response,.traceable to NIST (100 Hz to ±1dB point)-1 
    (M) metric mounting
    mounting threadM6 x 0.75 male  
    (W)-waterproof Cable
    electrical connectionintegrated cord with waterproof connection  

    9 other articles of the same category: