Basic data
Sensitivity (±10 %)100mV/g10.2 mV/(m/s²) 
 
Measuring range±50 gPK±490 m/s²PK 
 
Frequency range (≤5 %)2... 5,000 Hz  
 
Frequency range (±10 %)1.4... 6,500 Hz  
 
Resonance frequency≥25. 000 Hz  
 
Wide band resolution0.0002 g RMS0,002 m/s² RMS[2]
 
Linearity error±1 % [1]
 
Transverse acceleration sensitivity≤5 %  
Conditions of use
Overload limit (shock)±7.000 gPK±68.600 m/s²PK 
 
Temperature range (operation)-65... 250 ° F-54... 121 ° C
 
strain sensitivity (footprint)0.001 g/µε0.01 (m/s²)/µε[2]
specifications
power supply20... 30 V DC  
 
constant power supply2... 20 mA  
 
output impedance≤200Ω  
 
Bias voltage8... 12 V DC  
 
discharging charging time constant0.2... 0.8 s  
 
settling time
(auf Bias-Spannung ±10 %)
<5 s  
 
spectral noise (1 Hz)80 µg/√Hz785 (µm/s²)/√Hz[2]
 
spectral noise (10 Hz)15 µg/√Hz147 (µm/s²)/√Hz[2]
 
spectral noise (100 Hz)5 µg/√Hz49 (µm/s²)/√Hz[2]
 
Spectral noise (1,000 Hz)2 µg/√Hz20 (µm/s²)/√Hz[2]
 
Spectral noise (10,000 Hz)1 µg/√Hz9.8 (µm/s²)/√Hz[2]
Physical properties
Sensor elementCeramic  
 
Geometry of the sensor elementShear principle  
 
Housing materialTitanium  
 
SealingHermetic  
 
Size - height0.55 in14.0 mm 
 
Size - length0.80 in20.3 mm 
 
Size - width0.55 in14.0 mm 
 
Mass0.37 oz10.5 grams[2]
 
Electrical connection1/4 "-28 4-pin  
 
Connecting positionOn the side  
 
Mounting thread10-32 female thread  
 
Installation torque10... 20 in-lb113... 225 NCM 
Notes
[1]Zero-balance just, determined using the method of least squares  
 
[2]Typically  
 
[3]The data for temperatures above 121 ° C applies only for transducers with HT option.  
 
[4]The TEDS option increases the bias voltage by 1V.  
 
[5]Details: see PCBs Declaration of conformance PS023  
Included accessories
080A109Mount wax-1 
 
080A12Adhesive mounting-1 
 
080A90Superglue-1 
 
081B 05Mounting bolts (10-32 on 10-32)-1 
 
ACS-1TFrequency response for Triaxial accelerometer, traceable to NIST, 10 Hz to the oberen 5% frequency-1 
 
M081B05mounting bolts 10-32 to M6 x 0.75-1 
(A) glue Assembly
Accessories   
 
080A109mounting wax-1 
 
080A90cyano-1 
(J) ) Mass insulation
electrical insulation>100 MΩ  
 
size - height0.59 in15.0 mm 
 
size - length0.80 in20.3 mm 
 
size - width0.55 in14.0 mm 
 
mass0.37 oz10.5 grams 
 
Fixingbonding  
 
equipment   
 
080A109mounting wax-1 
 
080A90glue-1 < 
(HT) High temperature electronics
Frequency range (≤5 %)10... 5,000 Hz  
 
Frequency range (±10 %)7... 6,500 Hz  
 
Wide band resolution0.0005 g RMS0.005 µm / s ² RMS 
 
Temperature range65... 325 ° F-54... 163 ° C 
 
Supply voltage24... 30 V DC  
 
Bias voltage7... 16 V DC  
 
Discharge charge time constant0.03... 0.1 s  
 
Spectral noise (1 Hz)110 µg/√Hz1,080 (µm/s²)/√Hz 
 
Spectral noise (10 Hz)50 µg/√Hz491 (µm/s²)/√Hz 
 
Spectral noise (100 Hz)30 µg/√Hz294 (µm/s²)/√Hz 
 
Spectral noise (1).000 Hz)10 µg/√Hz98.1 (µm/s²)/√Hz 
(T) Ted's memory in accordance with IEEE PP1451. 4 < /.b >
Bias voltage8.7... 13.0 V DC  
(TLA) TEDS LMS International - free format
Bias voltage8.7... 13.0 V DC  
(TLB) TEDS LMS international - format for the automotive industry
Bias voltage8.7... 13.0 V DC  
(TLC) TEDS LMS international - format for the aviation industry
Bias voltage8.7... 13.0 V DC  
(TLD) Ted's memory in accordance with IEEE P1451. 4 < /.b >
Bias voltage8.7... 13.0 V DC  