PCB-(M)353B14
    zoom_out_map

      PCB-(M)353B14

    • ICP®-miniature vibration sensor,
    • Measuring range 1000 g,
    • Sensitivity 5 mV / g,
    • Frequency range 1 … 10,000 Hz,
    • Mass 1.8 grams,
    • 10-32 female connector above
    • basic data
      sensitivity (±10%)5 mV / g0.51 mV/(m/s²)
      range± 1.000 g pk ±9. 810 m/s² pk
      frequency range (±5%)1 … 10,000 Hz
      Frequency range (± 10%)0.7 … 18,000 Hz
      frequency range (± 3 dB)0.35 … 30,000 Hz
      Resonance frequency≥ 70,000 Hz
      wide band resolution0.01 g RMS0.1 m/s² RMS[1]
      Linearity≤ 1%[2]
      transverse acceleration sensitivity≤ 5%[3]
      conditions of use
      (Shock) overload limit± 10.000 g pk ±98.100 m/s² pk
      Temperature range (operation)-65 … 250 ° F-54 … 121 ° C
      Strain sensitivity (base area)≤ 0.005 g/µε≤ 0.05 (m/s²)/µε[1]
      technical characteristics
      Supply voltage18 … 30 V DC
      constant power supply2 … 20 mA
      Output impedance≤ 100 Ω
      Bias voltage8 … 12 V DC
      discharging charging time constant0.5 … 2.0 s
      Settling time < br(auf Bias-Spannung ±10 %)<5 s
      spectral noise (1 Hz)6,400 µg / √ Hz62.784 (µm / s ²) / √ Hz[1]
      spectral noise (10 Hz)1,400 µg / √ Hz13.734 (µm / s ²) / √ Hz[1]
      spectral noise (100 Hz)360 µg / √ Hz3.532 (µm / s ²) / √ Hz[1]
      Spectral noise (1,000 Hz)128 µg / √ Hz1.256 (µm / s ²) / √ Hz[1]
      Physical properties
      Size - height0.74 at18.8 mm
      Size - Allen9/32 in7.1 mm
      mass0.06 oz1.8 grams[1]
      sensor elementquartz
      Geometry of the sensor elementshear principle
      housing materialtitanium
      SealingHermetically sealed welded
      Electrical connection10-32-coaxial connector
      connection positionabove
      Mounting thread5-40 male
      Assembly torque8 … 12 in-lb90 … 135 NCM
      notes
      [1] Typically
      [2]zero-based balancing line, determined using the method of least squares
      [3]transverse acceleration sensitivity typically ≤ 3%
      [4]details: see PCBs Declaration of conformance PS023
      equipment
      080A109 Mount wax-1
      080A15adhesive mounting-1
      ACS-1 Frequency response, traceable to NIST (10 Hz up to the upper 5% point)-1
      (A) glue Assembly
      Accessories
      080A90cyano-1
      (M) metric mounting
      mounting threadM3 x 0.50 male
      equipment
      M080A15adhesive mounting-1
      (Q) increased discharge charge time constant
      frequency range (±5%)0.15 … 10,000 Hz
      Frequency range (± 10%)0.1 … 18,000 Hz
      Discharge charge time constant><5 s
      Settling time<5 s
      equipment
      ACS-97 Low frequency calibration of 1 … 10 Hz-1
      (B) reduced bias voltage
      Bias voltage4.5 … 7.5 V DC
      Power12 … 30 V DC
      constant power supply1 … 20 mA
      Measuring range600 g pk5.886 m/s² pk
      (J) Mass insulation
      frequency range (±5%)1 … 8,000 Hz
      frequency range (± 10%)0.7 … 15,000 Hz
      Resonance frequency56,000 Hz
      electrical insulation ≥100 MΩ
      size - hex3/8 in9.5 mm
      size - height0.82 in20.8 mm
      dimensions0.10 oz3.0 grams
      (W) Watertight cable connection
      connection positionabove
      PCB-(M)353B14

      Specific References

      Download

      353B14_drawing.PDF

      Technical drawing

      Download (51.93k)

      353B14_manual.PDF

      Operating instructions

      Download (1.76M)

      353B14_specs.PDF

      Technical data sheet

      Download (101.65k)