PCB-352C44

PCB-352C44

  • ICP®-miniature vibration sensor,
  • Masseisoliert,
  • Measurement range 50 g,
  • Sensitivity 100 mV/g,
  • Frequency range 1 … 8,000 Hz,
  • Mass of 3 grams,
  • 10-32 female connector above
  • basic data
    sensitivity (±10%)100 mV/g10.2 mV/(m/s²)
    range±50 g pk ±491 m/s 2 pk
    frequency range (±5%)1 … 8,000 Hz
    Frequency range (± 10%)0.5 … 10,000 Hz
    frequency range (± 3 dB)0.3 … 13,000 Hz
    Resonance frequency≥ 30,000 Hz
    wide band resolution0.0005 g RMS0.005 m/s² RMS[2]
    Linearity≤ 1%[3]
    transverse acceleration sensitivity≤ 5%
    conditions of use
    Overload limit±5. 000 g pk±49. 050 m/s² pk
    Temperature range-65… 250 ° F-54 … 121 ° C[1]
    specifications
    power supply22 … 30 V DC
    Constant power supply2 … 20 mA
    output impedance≤ 600 Ω
    Bias voltage8 … 15 V DC
    discharging charging time constant0.5 … 2.0 s
    Settling time < br(auf Bias-Spannung ±10 %)< 10 s
    spectral noise (1 Hz)120 µg / √ Hz1,177 (µm / s ²) / √ Hz[2]
    Spectral noise (10 Hz)30 µg / √ Hz294 (µm / s ²) / √ Hz[2]
    spectral noise (100 Hz)20 µg / √ Hz196 (µm / s ²) / √ Hz[2]
    spectral noise (1,000 Hz)6 µg / √ Hz59 (µm / s ²) / √ Hz[2]
    electrical insulation≥ 100 MΩΩ
    Physical properties
    size - height0.42 in10.7 mm
    size - hex7/16 in11.1 mm
    Mass0.10 oz3.0 grams[2]
    sensor elementceramic
    geometry of the sensor elementshear principle
    Housing materialtitanium
    sealinghermetically sealed welded
    Electrical connection10-32-coaxial socket
    Connection positionabove
    attachmentbonding
    notes
    [1]the data for Temperatures above 121 ° C shall apply only for transducers with HT option.
    [2]typically
    [3]zero-based balancing line, determined using the method of least squares
    [4]details: see PCBs Declaration of conformance PS023
    Equipment
    080A109mounting wax-1
    080A90 Cyano-1
    ACS-1frequency response, traceable to NIST (10 Hz up to the upper 5% point)-1
    (HT) high temperature electronics
    Frequency range (±5%)10 … 8,000 Hz
    frequency range (± 10%)8 … 10,000 Hz
    frequency range ( ±3 dB)4 … 13,000 Hz
    wide band resolution0.0005 g RMS0.005 m/s² RMS
    Temperature range-65 … 325 ° F-54 … 163 ° C
    supply24 … 30 V DC
    Discharging charging time constant0.04 … 0.12 s
    spectral noise(1 Hz)200 µg / √ Hz1,962 (µm / s ²) / √ Hz
    Spectral noise (10 Hz)70 µg / √ Hz686,7 (µm / s ²) / √ Hz
    spectral noise (100 Hz)10 µg / √ Hz98.1 (µm / s ²) / √ Hz
    Spectral noise (1,000 Hz)2 µg / √ Hz19.6 (µm / s ²) / √ Hz
    Bias voltage7 … 16 V DC
    (W) waterproof cable connection