PCB-(M)350D02
    zoom_out_map

      PCB-(M)350D02

      • ICP® shock acceleration sensor,
      • Masseisoliert,
      • With electric and mechanical filter,
      • Measuring range 50,000 g,
      • Sensitivity 0.1 mV / g,
      • Frequency range 4 … 10,000 Hz,
      • Integrated cable, length 3 m, ending on 10-32 plug
      basic data
      Sensitivity (± 30%)0.1 mV / g0.01 mV / (m / s)
      measuring range± 50,000 g pk± 490,000 m / spk
      Frequency range (± 1 dB)4 ... 10,000 Hz
      Frequency range (-3 dB)2 ... 25,000 Hz[4]
      Corner frequency of the electric filter (-3 dB)17,000 Hz[1] [2]
      Resonance frequency of the mechanical filter45,000 Hz[1] [3]
      resonant frequency≥100.000 Hz
      Broadband resolution0.5 g RMS4.9 m / s RMS[1]
      Linearity error (per 10,000 g / 98,100 m / s²)≤2,5%
      Lateral acceleration sensitivity≥7%
      Operating conditions
      Overload limit (shock)± 150,000 g pk1,471,500 ± m / s² pk
      The temperature range (operation)0 ... 150 ° F-18 ... 66 ° C
      Temperature range (storage)-40 ... 200 ° F-40 ... 93 ° C
      Technical characteristics
      supply voltage20 ... 30 V DC
      Constant current supply2 ... 20 mA
      output impedance≤200 Ω
      Bias voltage8 ... 14 V DC
      discharging0.10 s[1]
      Settling time 
      (on the bias voltage ± 10%)
      <1 s
      Electrical insulation (housing)> 1 M
      physical properties
      sensor elementceramics
      Geometry of the sensor elementshear principle
      housing materialtitanium
      sealhermetically sealed
      Size - Hexagon0.375 in9.5 mm
      Size - Height0.87 in22.1 mm
      Weight (without cable)0.16 oz4.5 grams[1]
      electrical connectionintegrated cable
      cable length10 ft3 m
      cable typeType 031, twisted pair
      mounting thread1/4 "-28 male thread
      Hints
      [1]typically,
      [2]second-order low-pass filter
      [3]The amplitude is increased by 9 dB in the range of the resonance frequency.
      [4]When given upper frequency limit is a guideline. The frequency response is limited by the combination of electrical and mechanical low pass filter.
      included supply
      ACS-14Hopkinson bar calibration for shock sensor-1
      ACS-22Frequency response, traceable to NIST (100 Hz to ± 1 dB point)-1
      (M) Metric assembly
      mounting threadM6 x 0.75 male
      PCB-(M)350D02

      Specific References

      Download

      350D02_drawing.PDF

      Technical drawing

      Download (93.86k)

      350D02_manual.PDF

      Operating instructions

      Download (1.67M)

      350D02_specs.PDF

      Technical data sheet