PCB-356A03

PCB-356A03

  • Triaxial ICP® miniature vibration sensor,
  • Mass 1 gram,
  • Measuring range 500 g
  • Sensitivity 10 mV / g,
  • Frequency range 2 … 8,000 Hz,
  • Integrated connection cable, length 1.5 m,
    ending on 4-pin female connector,
  • including extension cable, length 1.5 m,
    ending to three BNC
  • basic data
    sensitivity (±20%)10 mV / g1.02 mV/(m/s²)
    range±500 g pk ±4. 905 m/s 2 pk
    frequency (Y - and Z-axis) < br(≤5 %)2 … 8,000 Hz
    Frequency range (X-axis) (±5%)2 … 5,000 Hz
    frequency range (X-axis) (+ 1 dB)≥ 8,000 Hz
    Resonance frequency≥ 50,000 Hz
    Wide band resolution0.003 g RMS0.03 m/s² RMS[2]
    Linearity error≤ 1%[1]
    transverse acceleration sensitivity≤ 5%
    conditions of use
    Overload limit (shock)±5. 000 g PK±49. 050 m/s² pk
    Temperature range (operation)-65 … 250 ° F-54 … 121 ° C
    specifications
    power supply21 … 30 V DC
    Constant power supply2 … 20 mA
    output impedance≤ 100 Ω
    Bias voltage9 … 15 V DC
    Discharging charging time constant0.24 … 1,0 s
    settlingbr(auf Bias-Spannung ±10 %)< 3 s
    Spectral noise (1 Hz)1.200 ?g / √ Hz11.772 (µm / s ²) / √ Hz[2]
    spectral noise (10 Hz)300 µg / √ Hz2.943 (µm / s ²) / √ Hz[2]
    spectral noise (100 Hz)100 µg / √ Hz981 (µm / s ²) / √ Hz[2]
    spectral noise ( 1,000 Hz)30 µg / √ Hz294 (µm / s ²) / √ Hz[2]
    physical properties
    sensor elementceramic
    Geometrythe sensor elementshear principle
    housing materialtitanium
    sealinghermetic
    Size - height0.25 in6.35 mm
    size - length0.25 in6.35 mm
    Gr size - width0.25 in6.35 mm
    dimensions (without cable)0.04 oz1.0 grams[2]
    wiringintegrated cable
    Cable exitside
    cable termination1/4 "-28 4-pin socket
    " Cable length5 ft1.5 m
    cord typetype 034, 4-wire shielded cable
    attachmentbonding
    Notes
    [1]zero-based balancing line, determined using the method of least squares
    [2]typically
    [3]Details: See PCBs Declaration of conformance PS023
    Accessories
    034 G 054-wire shielded cables, 1.5 meter, 4-pin connector to three BNC-1
    080A109mounting wax-1
    080A90cyano-1
    ACS-1 Tfrequency response for Triaxial accelerometer, traceable to NIST, 10 Hz up to the top 5% -. Frequency-1