PCB-(M)260A03

PCB-(M)260A03

  • Triaxial ICP® power sensor,
  • Measuring range (Z axis) 44.5 kN,
  • Measuring range (X - and Y-axes) 17.8 kN,
  • Sensitivity (Z-axis) 0.06 mV / N,
  • Sensitivity (X - and Y-axes) 0.28 mV / N,
  • Frequency range (Z axis) 0.01 … 39,000 Hz,
  • Frequency range (X - and Y-axes) 0.001 … 39,000 Hz,
  • 4-pin female connector on the side
  • basic data
    sensitivity (Z axis) (±20%)0.25 mV / Nlb/0.06 mV / N[2] [3]
     
    sensitivity (X - and Y-axes) (±20%)1.25 mV / lb0.28 mV / N[2] [3]
     
    Measuring range (Z axis)10,000 lb44.48 kN 
     
    measuring range (X - and Y-axes)4,000 lb17.79 kN 
     
    maximum power ( Z-Achse)11,000 lb48,93 kN 
     
    maximum force (X - and Y-axes)4,400 lb19.57 kN 
     
    maximum moment (Z-axis)240 ft-lb325,4 Nm 
     
    maximum moment (X - and Y-axes)325 ft-lb440,7 Nm 
     
    wide band resolution (Z axis)0.05 lb RMS0,222 N RMS[1]
     
    Wide band resolution (X - and Y-axes)0.01 lb RMS0.04 N RMS[1]
     
    Upper frequency limit39,000 Hz  
     
    bottomCutoff frequency (Z axis) (-5%)0.01 Hz  
     
    lower limiting frequency (X - and Y-axes) (-5%)0.001 Hz  
     
    linearity?1 % FS [4]
     
    crosstalk (between X - and Y-axis)±3%  
     
    crosstalk (between X and y axis and Z axis)≤5%  
    Conditions of use
    temperature range-65 … 250 ° F-54 … 121 ° C 
    technical
    maximum Output signal (Z axis)±2.5 V DC  
     
    maximum output signal (X - and Y-axes)±5 V DC  
     
    Discharging charging time constant (Z axis)≥ 50 s  
     
    discharging charging time constant (X - and Y-axes)≥ 500 s  
     
    Supply voltage (all axes)20 … 30 V DC  
     
    constant power supply (all axes)2 &Emmap; 20 mA  
     
    output impedance≤100 Ω  
     
    Bias voltage8 … 14 V DC  
     
    Spectral noise (X - and Y-axes) (1 Hz)0.003 lb / √Hz0,0134 N / √Hz 
     
    spectral noise (X - and Y-axes) (10 Hz)0.001 lb / √Hz0,00445 N / √Hz 
     
    spectral noise (X - and Y-axes) (100 Hz)0.0004 lb / √Hz0,00178 N / √Hz 
     
    spectral noise (X - and Y-axis) (1,000 Hz)0.0001 lb / √Hz0,000445 N / √Hz 
     
    Spectral noise (Z axis) (1 Hz)0.02 lb / √Hz0,089 N / √Hz 
     
    spectral noise (Z axis) (10 Hz)0.005 lb / √Hz0,0222 N / √Hz 
     
    spectral noise (Z axis) (100 Hz)0.002 lb / √Hz0,0089 N / √Hz 
     
    spectral noise (Z axis) (1,000 Hz)0.0005 lb / √Hz0,00222 N / √Hz 
     
    output polaritypositive  
    Physical properties
    Preload40,000 lb178 kN[5]
     
    Stiffness (Z-axis)40 lb/µin7 kN/µm[1]
     
    rigidity (X - and Y-axes)15 lb/µin2.6 kN/µm[1]
     
    Size - height0,790 in20.07 mm 
     
    size - length2.25 in57.1 mm 
     
    size -. Wide2.25 in57.1 mm 
     
    size - inner diameter1,023 in25,98 mm 
     
    size - diameter of the Messoberflä Che1,800 in45.72 mm 
     
    mass9.56 oz271 grams 
     
    housing materialstainless steel  
     
    Sealinghermetically sealed  
     
    electrical connection4-Pin  
     
    connection positionside  
    Notes
    [1]typically  
     
    [2]at witg of the recommended preload. The sensitivities can depending on the preload to ±5% change.  
     
    [3]the specified sensitivities are valid only when using the supplied bolt.  
     
    [4]zero-based balancing line, determined using the method of least squares  
     
    [5]the preload should be at least ten times the be on the X - and Y-axis of used operating range.  
     
    [6]details: see PCBs Declaration of conformance PS023  
    equipment
    081A71mounting bolt-1 
     
    082 B 06washer-1 
     
    083A11mounting sleeve-1 
    (W) waterproof cable connection
    Cable exitside  
    (M) metric mounting
    equipment   
     
    M081A71Mounting bolt-1 

    9 other articles of the same category: