PCB-(M)261A12

PCB-(M)261A12

  • Triaxial strength measuring element with charge output,
  • Measuring range (Z axis) 4.45 kN,
  • Measuring range (X - and Y-axes) 4.45 kN,
  • Sensitivity (Z-axis) 3.4 pC/N,.
  • Sensitivity (X - and Y-axes) 7.2 pC/N,.
  • Upper frequency limit 10,000 Hz,.
  • Three 10-32 connectors on the side
  •  

    basic data
    sensitivity (X - and Y-axes) (±15%)32 pC/lb7.19 pC/N[1]
     
    sensitivity (Z axis) (±15%)15 pC/lb3,37 pC/N[1]
     
    measuring range (Z axis)1,000 lb4.45 kN 
     
    measuring range (X - and Y-axes)1,000 lb4.45 kN 
     
    Maximum power (Z axis)1,320 lb5.87 kN 
     
    maximum force (X - and Y-axes)1,000 lb4.45 kN 
     
    maximum moment (Z axis)40 ft-lb54,23 Nm 
     
    maximum moment (X - and Y-axes)70 ft-lb94,91 Nm 
     
    upper cut-off frequency10,000 Hz  
     
    Linearity≤ 1% FS [2]
     
    crosstalk (between X - and Y-axis)±3%  
     
    Crosstalk (between X and y axis and Z axis)≤5%  
    Conditions of use
    temperature range-100 … 350 ° F-73 … 177 ° C 
    Technical characteristics
    capacity (all axes)30 pF [3]
     
    Insulation resistance (all axes)≥1,000,000 MΩ  
     
    output polarity (towards the marks)negative  
    Physical properties
    Rigidity (Z axis)19 lb/µin3.3 kN/µm[3]
     
    Rigidity (X - and Y-axes)6 lb/µin1 kN/µm[3]
     
    mass34.40 oz975 grams 
     
    parts usematerialstainless steel  
     
    sealinghermetically sealed  
     
    electrical connectionthree 10-32-coaxial connectors  
     
    Connection positionside  
    notes
    [1]preload when using the recommended. The sensitivities can depending on the preload to ±5% change.  
     
    [2]zero-based balancing line, determined using the method of least squares  
     
    [3]typically  
    (W)Watertight cable connection
    Cable outletOn the side  

    5 other articles of the same category: