PCB-(M)261A11

PCB-(M)261A11

  • Triaxial strength measuring element with charge output,
  • Measuring range (Z axis) 4.45 kN,
  • Measuring range (X - and Y-axes) 2.22 kN,
  • Sensitivity (Z-axis) 3.4 pC/N,.
  • Sensitivity (X - and Y-axes) 7.2 pC/N,.
  • Upper frequency limit 10,000 Hz,.
  • Three 10-32 connectors on the side
  • of
    basic data
    sensitivity (Z axis) (±15%)15 pC/lb3.37 pC/N[1]
    sensitivity (X - and Y-axes) (±15%)32 pC/lb7.19 pC/N[1]
    measuring range (Z axis)1,000 lb4.45 kN
    measuring range (X - and Y-axes)500 lb2.22 kN
    Maximum power (Z axis)1,320 lb5.87 kN
    Maximum force (X - and Y-axes)660 lb2,94 kN
    maximum moment (Z-axis)14 ft-lb18.98 Nm
    maximum Moment (X - and Y-axes)13 ft-lb17,63 Nm
    upper cut-off frequency10,000 Hz
    linearity≤ 1% FS[2]
    Crosstalk (between X - and Y-axis)±3%
    crosstalk (between X and y axis and Z axis)≤5%
    Conditions of use
    Temperature range-100 … 350 ° F-73 … 177 ° C
    Technical characteristics
    capacity (all axes)18 pF[3]
    insulation resistance (all axes)≥ 1,000,000 M Ω
    Output polarity (towards the marks)negative
    physical properties
    stiffness (Z axis)10 lb/µin1.75 kN/µm[3]
    Rigidity (X - and Y-axes)4 lb/µin0.7 kN/µm[3]
    mass13.60 oz386 grams
    parts usematerialstainless steel
    sealinghermetically sealed
    electrical connectionthree 10-32-coaxial connectors
    Connection positionside
    notes
    [1]preload when using the recommended. The sensitivities can depending on the preload to ±5% change.
    [2]zero-based balancing line, determined using the method of least squares
    [3]typically
    (W)Watertight cable connection
    cable exitside
    (M) metric mounting
    equipment
    M081A70mounting bolts-1