PCB-356M57/NC

PCB-356M57/NC

  • Triaxial ICP® miniature vibration sensor for vacuum applications,
  • Low outgassing
  • Measuring range 500 g
  • Sensitivity 10 mV / g,
  • Frequency range 2 … 7,000 Hz,
  • Weight 4 grams,
  • Integrated connection cable, length 1.5 m,
    ending on 4-pin female connector,
  • without extension cable
  • basic data
    sensitivity (±10%)10 mV / g1.02 mV/(m/s²)
    range±500 g pk ±4. 905 m/s 2 pk
    frequency (Y - and Z-axis) < br(≤5 %)2 … 10,000 Hz
    Frequency range (X-axis) (±5%)2 … 7,000 Hz
    resonance frequency≥ 55,000 Hz
    Wide band resolution0.003 g RMS0.03 m/s² RMS[1]
    linearity error≤ 1%[4]
    transverse acceleration sensitivity≤ 5%
    conditions of use
    Overload limit (shock) ±10. 000 g pk ±98.100 m/s² pk
    temperature range (operation)-65 … 250 ° F-54 … 121 ° C
    specifications
    power supply18 … 30 V DC
    Constant power supply2 … 20 mA
    output impedance≤200Ω
    Bias voltage7 … 11 V DC
    Discharging charging time constant0.3 … 1,0 s
    settlingbr(auf Bias-Spannung ±10 %)< 3 s
    Spectral noise (1 Hz)1,000 µg / √ Hz9.810 (µm / s ²) / √ Hz[1]
    spectral noise (10 Hz)300 µg / √ Hz2.943 ( µm / s ²) / √ Hz[1]
    spectral noise (100 Hz)80 µg / √ Hz785 (µm / s ²) / √ Hz[1]
    spectral noise ( 1,000 Hz)25 µg / √ Hz308 (µm / s ²) / √ Hz[1]
    physical properties
    sensor elementceramic
    Geometry of the sensor elementshear principle
    housing materialtitanium
    sealinghermetically sealed welded
    Size - height0.4 in10.2 mm
    size - length0.4 in10.2 mm
    Size - width0.4 in10.2 mm
    dimensions (without cable)0.14 oz4 grams[1]
    wiring Integrated cable[3]
    cable exitside
    cable termination1/4 "-28 4-pin socket
    "
    Cable length5 ft1.5 m
    cord typetype 034, 4-wire shielded cable[2]
    mounting thread5-40 female
    Assembly torque4 … 5 in-lb45 … 56 NCM
    notes
    [1]typically
    [2]The only outgasing material is the Teflon is used for the cable sheath.
    [3]TML: ≤ 1% CVCM: ≤ 0.1%
    [4]zero-based balancing line, determined using the method of least squares
    [5]details: see PCBs Declaration of conformance PS023
    Accessories
    080A Adhesive mounting-1
    080A109mounting wax-1
    081A27mounting bolts, 5-40 on 5-40-1
    081A90mounting bolts, 10-32 on 5-40-1
    ACS-1 Tfrequency response for triaxialen Transducer, traceable to NIST, 10 Hz up to the upper 5% frequency-1
    M081A27metric mounting bolts, 5-40 M3 x 0.50-1

    30 other articles of the same category: