PCB-M1631-04C

PCB-M1631-04C

  • S type load cell,
  • Measuring range≥ 10 kΩ,
  • Nominal 2 mV / V,
  • Integrated cable, length 3 m,
    ending on open ends
  • basic data
    measuring range2.248 lb≥ 10 kΩ[1]
    value (±10%)2 mV / V[2]
    linearity error&le≤0.15% FS
    hysteresis&le≤0.15% FS
    repeatability≤ 0.05 %RO
    Resonance frequency2,400 Hz
    creep error≤ 0.08%
    conditions
    Ü berlastlimit3.372 lb15 kN
    maximum capacity < br(Seitlich einwirkende Kraft, FX oder FY) )225 lb1000 N[4]
    maximum capacity < br(Biegemoment, MX oder MY) 450 in-lb50.8 Nm[4]
    maximum capacity < br(Axiales Drehmoment, MZ)450 lb50.8 Nm[4]
    Temperature range (operation)0 …200 °F18 … 93 ° C
    temperature range (offset)75 … 150 ° F21 … 65 ° C
    temperature impact on the Output (max)±0, 002% of reading / ° F±0, 0036% of reading / ° C[3]
    temperature effect on zero signal deviation (maximum)±0. 00≤5 %FS/°F/±0, 027% FS / ° C[3]
    technical characteristics
    Bridge resistance350 Ω[2]
    supply voltage (recommended)10 V DC[5]
    insulation resistance> 5,000 M Ω
    Zero signal deviation≤ 1% FS
    output polaritypositive when pull
    physical properties
    size -. Length2.00 in51.0 mm[6]
    size - height3.0 in76.2 mm
    size - width1.0 in25.4 mm
    Weight1.2 lb544 g
    Housing materialnickel plated steel
    sensor elementstrain
    stretch at Full load0.003 in0.05 mm
    wiringintegrated cable, length 3 m
    cable outletlateral
    Notes
    [1]FS = "Full Scale": full scale
    [2]nominal
    [3]Over the compensated temperature range
    [4]insulated load the load cell with the named power or with the designated moment < br(keine zusätzlichen Belastungen)
    [5 ]Calibrated with 10 V DC supply voltage; Power supply with 5 … 20 V DC or V AC RMS possible
    [6]details of the dimensions : see technical drawing